Literature DB >> 12663143

Comparing modified and plain peptide linked enzyme immunosorbent assay (ELISA) for detection of human immunodeficiency virus type-1 (HIV-1) and type-2 (HIV-2) antibodies.

M Manocha1, K T Chitralekha, M Thakar, D Shashikiran, R S Paranjape, D N Rao.   

Abstract

Serological diagnosis of human immunodeficiency virus (HIV) based on detection of HIV antibodies is one of the easiest, cheapest and simplest assay. Synthetic peptides corresponding to immunodominant regions of envelope glycoprotein (gp41, V3 loop for HIV-1 and gp36 for HIV-2) were used in the present study, to detect the anti-HIV antibodies in sera of Sexually Transmitted Diseases (STD), Tuberculosis (TB), Anti-Natal Care (ANC) patients. About 550 serum samples were tested using Enzyme Linked Immunosorbent Assay (ELISA) technique. The human sera positive for antibody to HIV-1 and HIV-2, reacted to different degrees with these peptides when used as a plain peptide with or without CGG motif/biotin motif at the amino terminus. The selected sequences are of Indian strain with 'C' serotype. The results showed a 100% sensitivity and specificity for V3 loop peptide and 98% sensitivity and specificity for gp41 peptide containing CGG moiety while the plain peptides showed similar sensitivities but low specificity's, i.e. 98% for V3 loop peptide and 42% for gp41 peptide when reacted with HIV-1 positive sera. The presence of biotin at the amino terminus did not provide any beneficial effect in increasing the sensitivity although the specificity was enhanced for both the peptide sequences, i.e. gp41 and V3 loop peptide. Furthermore, the gp36 peptide containing CGG moiety detected the HIV-2 sera with 100% sensitivity and 98% specificity while the sensitivity and specificity of gp36 plain peptide was reduced to 98 and 90%. Thus the study overall highlighted the importance of synthetic peptides containing CGG moiety as a capture antigen in detecting both HIV-1 & 2 sera using an indigenously built ELISA system which is simple, cheap, sensitive and cost effective for rural areas.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12663143     DOI: 10.1016/s0165-2478(02)00257-2

Source DB:  PubMed          Journal:  Immunol Lett        ISSN: 0165-2478            Impact factor:   3.685


  3 in total

1.  Use of a new dual-antigen enzyme-linked immunosorbent assay to detect and characterize the human antibody response to the human immunodeficiency virus type 2 envelope gp125 and gp36 glycoproteins.

Authors:  José Maria Marcelino; Helena Barroso; Fátima Gonçalves; Sofia Marques Silva; Carlos Novo; Perpétua Gomes; Ricardo Camacho; Nuno Taveira
Journal:  J Clin Microbiol       Date:  2006-02       Impact factor: 5.948

2.  Serodiagnosis of Echinococcus spp. infection: explorative selection of diagnostic antigens by peptide microarray.

Authors:  Claudia List; Weihong Qi; Eva Maag; Bruno Gottstein; Norbert Müller; Ingrid Felger
Journal:  PLoS Negl Trop Dis       Date:  2010-08-03

3.  Problems encountered in conventional HIV 1/2 Algorithms: lack of necessity for immunoblot assays to confirm repeated ELISA reactive results.

Authors:  Pelin Yuksel; Suat Saribas; Mert Kuskucu; Sibel Islak Mutcali; Erdogan Kosan; Zafer Habip; Mehmet Demirci; Eda Salihoglu Kara; Ilhan Birinci; Reyhan Caliskan; Harika Oyku Dinc; Kenan Midilli; Tevhide Ziver; Bekir Kocazeybek
Journal:  Afr Health Sci       Date:  2018-06       Impact factor: 0.927

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.