Literature DB >> 12660116

Calculation of electric fields induced by body and head motion in high-field MRI.

Feng Liu1, Huawei Zhao, Stuart Crozier.   

Abstract

In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength.

Entities:  

Mesh:

Year:  2003        PMID: 12660116     DOI: 10.1016/s1090-7807(02)00180-5

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  7 in total

Review 1.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 2.  Safety concerns related to magnetic field exposure.

Authors:  Amanda K Andriola Silva; Erica L Silva; E Sócrates T Egito; Artur S Carriço
Journal:  Radiat Environ Biophys       Date:  2006-09-21       Impact factor: 1.925

Review 3.  Gradient and shim technologies for ultra high field MRI.

Authors:  Simone A Winkler; Franz Schmitt; Hermann Landes; Joshua de Bever; Trevor Wade; Andrew Alejski; Brian K Rutt
Journal:  Neuroimage       Date:  2016-11-30       Impact factor: 6.556

Review 4.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

Review 5.  Biological effects and safety in magnetic resonance imaging: a review.

Authors:  Valentina Hartwig; Giulio Giovannetti; Nicola Vanello; Massimo Lombardi; Luigi Landini; Silvana Simi
Journal:  Int J Environ Res Public Health       Date:  2009-06-10       Impact factor: 3.390

6.  Effects of receive-only inserts on specific absorption rate, B1 (+) field, and Tx coil performance.

Authors:  Narayanan Krishnamurthy; Tiejun Zhao; Tamer S Ibrahim
Journal:  J Magn Reson Imaging       Date:  2013-08-01       Impact factor: 4.813

7.  Investigation of assumptions underlying current safety guidelines on EM-induced nerve stimulation.

Authors:  Esra Neufeld; Ioannis Vogiatzis Oikonomidis; Maria Ida Iacono; Leonardo M Angelone; Wolfgang Kainz; Niels Kuster
Journal:  Phys Med Biol       Date:  2016-05-25       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.