Literature DB >> 12658763

Non-invasive assessment of coronary flow velocity reserve: a new method using transthoracic Doppler echocardiography.

Ya Yang1, Thomas Bartel, Holger Eggebrecht, Loredana Latina, Clemems von Birgelen, Guido Caspari, Xinfang Wang, Raimund Erbel.   

Abstract

Transthoracic Doppler echocardiography (TTDE) allows noninvasive flow measurement in the distal left anterior descending artery (LAD). The feasibility of detecting coronary flow by contrast-enhanced TTDE with second harmonic technique was assessed, the coronary flow velocity reserve (CFVR) was evaluated in comparison to intracoronary Doppler flow (ICD) analysis and the CFVR after PTCA in LAD was investigated. In 77 (96%) of 80 patients, CFVR was successfully determined with intravenous adenosine infusion. Doppler signal quality was evaluated in the first 46 patients by use of intravenous Levovist infusion and second harmonic technique. The Doppler flow was not visible in 1. patient only. CFVR determined from TTDE (2.77 +/- 0.65) was correlated closely with those from ICD (2.88 +/- 0.78) measurements (y = 0.73x + 0.67, r = 0.87, P < 0.001). In conclusion, TTDE is a feasible method and provides reliable data on CFVR which can be used for follow-up after PTCA.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12658763     DOI: 10.1007/BF02857683

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  15 in total

1.  Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of levovist.

Authors:  T Bartel; S Müller; D Baumgart; B T Mathew; M Haude; R Erbel
Journal:  J Am Soc Echocardiogr       Date:  1999-04       Impact factor: 5.251

2.  Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.

Authors:  J W Doucette; P D Corl; H M Payne; A E Flynn; M Goto; M Nassi; J Segal
Journal:  Circulation       Date:  1992-05       Impact factor: 29.690

3.  Comparison of coronary vasodilation with intravenous dipyridamole and adenosine.

Authors:  J D Rossen; J E Quillen; A G Lopez; R G Stenberg; C L Talman; M D Winniford
Journal:  J Am Coll Cardiol       Date:  1991-08       Impact factor: 24.094

4.  Transesophageal echocardiography. New window to coronary arteries and coronary blood flow.

Authors:  R Erbel
Journal:  Circulation       Date:  1991-01       Impact factor: 29.690

5.  Improved assessment of coronary stenosis severity using the relative flow velocity reserve.

Authors:  D Baumgart; M Haude; G Goerge; J Ge; S Vetter; N Dagres; G Heusch; R Erbel
Journal:  Circulation       Date:  1998-07-07       Impact factor: 29.690

6.  Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment.

Authors:  C Caiati; N Zedda; C Montaldo; R Montisci; S Iliceto
Journal:  J Am Coll Cardiol       Date:  1999-07       Impact factor: 24.094

7.  Effects of adenosine on human coronary arterial circulation.

Authors:  R F Wilson; K Wyche; B V Christensen; S Zimmer; D D Laxson
Journal:  Circulation       Date:  1990-11       Impact factor: 29.690

8.  Improved Doppler signal intensity in coronary arteries after intravenous peripheral injection of a lung-crossing contrast agent (SHU 508A)

Authors:  S Iliceto; C Caiati; P Aragona; R Verde; R Schlief; P Rizzon
Journal:  J Am Coll Cardiol       Date:  1994-01       Impact factor: 24.094

9.  Effect of basal epicardial tone on endothelium-independent coronary flow reserve measurement.

Authors:  D Hasdai; D R Holmes; S T Higano; A Lerman
Journal:  Cathet Cardiovasc Diagn       Date:  1998-08

10.  Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: comparison with invasive technique.

Authors:  T Hozumi; K Yoshida; T Akasaka; Y Asami; Y Ogata; T Takagi; S Kaji; T Kawamoto; Y Ueda; S Morioka
Journal:  J Am Coll Cardiol       Date:  1998-11       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.