Literature DB >> 12657147

Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.

E Schäfer1, R Schlingemann.   

Abstract

AIM: To determine the cleaning effectiveness and the shaping ability of K3 nickel-titanium rotary instruments and stainless steel hand K-Flexofiles during the preparation of curved root canals in extracted human teeth.
METHODOLOGY: A total of 60 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into two groups of 30 canals. Based on radiographs taken prior to instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared by K3 instruments using a crown-down preparation technique or by K-Flexofiles using a reaming motion up to size 35. After each instrument, the root canals were flushed with 5 mL of a 2.5% NaOCl solution and at the end of instrumentation with 5 mL of saline. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. After splitting the roots longitudinally, the amount of debris and smear layer were quantified on the basis of a numerical evaluation scale, using a scanning electron microscope. The data established for scoring the debris and the smear layer were separately recorded and analysed statistically using the Wilcox-on's test.
RESULTS: None of the stainless steel K-Flexofiles but 5 K3 nickel-titanium instruments separated. Completely clean root canals were never observed. For debris removal, K-Flexofiles achieved significantly better results (P < 0.001) than K3 instruments. The results for remaining smear layer were similar (P > 0.05). K3 instruments maintained the original canal curvature significantly better (P < 0.0001) than K-Flexofiles. No significant differences were detected between the instruments (P > 0.05) for the time taken to prepare the canals.
CONCLUSIONS: Under the conditions of this study, K-Flexofiles allowed significantly better removal of debris than K3 instruments. K3 files maintained the original curvature significantly better. A number of K3 instruments fractured.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12657147     DOI: 10.1046/j.1365-2591.2003.00644.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  26 in total

1.  Appearance of the root canal walls after preparation with NiTi rotary instruments: a comparative SEM investigation.

Authors:  Carlo Prati; Federico Foschi; Cesare Nucci; Lucio Montebugnoli; Silvia Marchionni
Journal:  Clin Oral Investig       Date:  2004-02-04       Impact factor: 3.573

2.  Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

Authors:  M Manjunatha; Kini Annapurna; V Sudhakar; Vc Sunil Kumar; Vinay Kumar Hiremath; Ankur Shah
Journal:  J Int Oral Health       Date:  2013-02-26

3.  Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni- Ti files - An In-Vitro SEM study.

Authors:  J M V Raghavendra Reddy; Prasanna Latha; Basavana Gowda; Varadendra Manvikar; D Benal Vijayalaxmi; Kalyana Chakravarthi Ponangi
Journal:  J Int Oral Health       Date:  2014-02-26

4.  Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.

Authors:  Haridoss Selvakumar; Swaminathan Kavitha; Eapen Thomas; Vasanthakumari Anadhan; Rajendran Vijayakumar
Journal:  J Clin Diagn Res       Date:  2016-01-01

5.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

6.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

7.  Evaluation of apical deviation in root canals instrumented with K3 and ProTaper systems.

Authors:  Mariana Diniz Bisi dos Santos; Marília Fagury Marceliano; Patrícia Rodrigues de Almeida Silva E Souza
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

8.  Histological analysis of cleaning efficacy of hand and rotary instruments in the apical third of the root canal: A comparative study.

Authors:  Ashtha Arya; Dildeep Bali; Mandeep S Grewal
Journal:  J Conserv Dent       Date:  2011-07

9.  Shaping ability of nickel-titanium rotary instruments in curved root canals.

Authors:  Ali Talati; Saeed Moradi; Maryam Forghani; Ali Monajemzadeh
Journal:  Iran Endod J       Date:  2013-05-01

10.  Effects of preparation techniques on root canal shaping assessed by micro-computed tomography.

Authors:  Miranda Stavileci; Veton Hoxha; Ömer Görduysus; Ilkan Tatar; Kjell Laperre; Jeroen Hostens; Selen Küçükkaya; Merita Berisha
Journal:  Med Sci Monit Basic Res       Date:  2013-06-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.