Literature DB >> 12656325

Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber.

Yimin Wang1, Yonghua Zhao, J S Nelson, Zhongping Chen, Robert S Windeler.   

Abstract

We have developed an ultrahigh-resolution optical coherence tomographic system in which broadband continuum generation from a photonic crystal fiber is used to produce high longitudinal resolution. Longitudinal resolution of 1.3-microm has been achieved in a biological tissue by use of continuum light from 800 to 1400 nm. The system employed a dynamic-focusing tracking method to maintain high lateral resolution over a large imaging depth. Subcellular imaging is demonstrated.

Mesh:

Year:  2003        PMID: 12656325     DOI: 10.1364/ol.28.000182

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  7 in total

1.  Broadband superluminescent diode-based ultrahigh resolution optical coherence tomography for ophthalmic imaging.

Authors:  Dexi Zhu; Meixiao Shen; Hong Jiang; Ming Li; Michael R Wang; Yuhong Wang; Lili Ge; Jia Qu; Jianhua Wang
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

2.  Extended bandwidth wavelength swept laser source for high resolution optical frequency domain imaging.

Authors:  Sahar Hosseinzadeh Kassani; Martin Villiger; Néstor Uribe-Patarroyo; Changsu Jun; Reza Khazaeinezhad; Norman Lippok; Brett E Bouma
Journal:  Opt Express       Date:  2017-04-03       Impact factor: 3.894

3.  Lateral resolution improvement of oversampled OCT images using Capon estimation of weighted subvolume contribution.

Authors:  Evgenia Bousi; Ioanna Zouvani; Costas Pitris
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

4.  Ultrawideband photonic crystal fiber coupler for multiband optical imaging system.

Authors:  Seon Young Ryu; Hae Young Choi; Eun Seo Choi; Ivan Tomov; Zhongping Chen; Byeong Ha Lee
Journal:  Appl Opt       Date:  2010-04-01       Impact factor: 1.980

5.  Improving lateral resolution and image quality of optical coherence tomography by the multi-frame superresolution technique for 3D tissue imaging.

Authors:  Kai Shen; Hui Lu; Sarfaraz Baig; Michael R Wang
Journal:  Biomed Opt Express       Date:  2017-10-06       Impact factor: 3.732

6.  Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

Authors:  David Huang; Maolong Tang; Li Wang; Xinbo Zhang; Rebecca L Armour; Devin M Gattey; Lorinna H Lombardi; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

7.  Micrometer axial resolution OCT for corneal imaging.

Authors:  Rahul Yadav; Kye-Sung Lee; Jannick P Rolland; James M Zavislan; James V Aquavella; Geunyoung Yoon
Journal:  Biomed Opt Express       Date:  2011-10-06       Impact factor: 3.732

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.