Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer.

Gert J Meijer1, Coen Rasch, Peter Remeijer, Joos V Lebesque.   

Abstract

PURPOSE: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). METHODS AND MATERIALS: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients.
RESULTS: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 mm, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course.
CONCLUSION: Anisotropic margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation.

Entities:  

Mesh:

Year:  2003        PMID: 12654438     DOI: 10.1016/s0360-3016(02)04162-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  21 in total

1.  A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

Authors:  Bongile Mzenda; Mir Hosseini-Ashrafi; Antony Palmer; Honghai Liu; David J Brown
Journal:  Med Biol Eng Comput       Date:  2010-04-23       Impact factor: 2.602

Review 2.  Image-guided radiation therapy for muscle-invasive bladder cancer.

Authors:  Juliette Thariat; Shafak Aluwini; Qiong Pan; Mickael Caullery; Pierre-Yves Marcy; Martin Housset; Jean-Leon Lagrange
Journal:  Nat Rev Urol       Date:  2011-11-08       Impact factor: 14.432

3.  CTV to PTV margins for prostate irradiation. Three-dimensional quantitative assessment of interfraction uncertainties using portal imaging and serial CT scans.

Authors:  Luis A Pérez-Romasanta; Eva Lozano-Martín; Joaquín Velasco-Jiménez; Fermín Mendicote-León; Miguel Sanz-Martín; Javier Torres-Donaire; Carmen Carrascosa-Fernández; Juan Carlos Zapata-Jimínez; Jacinto Arjona-Gutiérrez; Antonio Gil-Agudo
Journal:  Clin Transl Oncol       Date:  2009-09       Impact factor: 3.405

Review 4.  Bladder-sparing approaches to invasive disease.

Authors:  Jason A Efstathiou; Anthony L Zietman; Donald S Kaufman; Niall M Heney; John J Coen; William U Shipley
Journal:  World J Urol       Date:  2006-11       Impact factor: 4.226

5.  A retrospective review of the long-term outcomes of online adaptive radiation therapy and conventional radiation therapy for muscle invasive bladder cancer.

Authors:  Janice Yeh; Mathias Bressel; Keen Hun Tai; Tomas Kron; Farshad Foroudi
Journal:  Clin Transl Radiat Oncol       Date:  2021-08-06

6.  Independent position correction on tumor and lymph nodes; consequences for bladder cancer irradiation with two combined IMRT plans.

Authors:  Dominique C van Rooijen; René Pool; Jeroen B van de Kamer; Maarten C C M Hulshof; Caro C E Koning; Arjan Bel
Journal:  Radiat Oncol       Date:  2010-06-15       Impact factor: 3.481

7.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

8.  Definitive, intensity modulated tomotherapy with a simultaneous integrated boost for prostate cancer patients - Long term data on toxicity and biochemical control.

Authors:  Kilian Schiller; Michael Geier; Marciana Nona Duma; Carsten Nieder; Michael Molls; Stephanie E Combs; Hans Geinitz
Journal:  Rep Pract Oncol Radiother       Date:  2019-05-30

9.  The effect of on-line position correction on the dose distribution in focal radiotherapy for bladder cancer.

Authors:  Dominique C van Rooijen; Jeroen B van de Kamer; René Pool; Maarten C C M Hulshof; Caro C E Koning; Arjan Bel
Journal:  Radiat Oncol       Date:  2009-09-24       Impact factor: 3.481

10.  New target volume delineation and PTV strategies to further personalise radiotherapy.

Authors:  David Bernstein; Alexandra Taylor; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2021-02-25       Impact factor: 3.609