Literature DB >> 12652572

A DNA sieving matrix with thermally tunable mesh size.

Cheuk Wai Kan1, Annelise E Barron.   

Abstract

We present a "proof-of-concept" study showing that a blend of thermo-responsive and nonthermo-responsive polymers can be used to create a DNA sieving matrix with a thermally tunable mesh size, or "dynamic porosity". Various blends of two well-studied sieving polymers for CE, including hydroxypropylcellulose (HPC), a thermo-responsive polymer, and hydroxyethylcellulose (HEC), a nonthermo-responsive polymer, were used to separate a double-stranded DNA restriction digest (Phi X174-HaeIII). HPC exhibits a volume-phase transition in aqueous solution which results in a collapse in polymer coil volume at approximately 39 degrees C. Utilizing a blend of HPC and HEC in a ratio of 1:5 by weight, we investigated the effects of changing mesh size on DNA separation, as controlled by temperature. High-resolution DNA separations were obtained with the blended matrix at temperatures ranging from 25 degrees C to 38 degrees C. We evaluated changes in the selectivity of DNA separation with increasing temperature for certain pairs of small and large fragments. A pure HEC (nonthermo-responsive) matrix was used over the same temperature range as a negative control. In the blended matrix, we observe a maximum in selectivity at approximately 31 degrees C for small DNA, while a significant increase in the selectivity of large-DNA separation occurs at approximately 36 degrees C as the polymer mesh "opens". We also demonstrate, through a temperature ramping experiment, that this matrix can be utilized to obtain high-resolution separation of both small and large DNA fragments simultaneously in a single CE run. Blended polymer matrices with "dynamic porosity" have the potential to provide enhanced genomic analysis by capillary array or microchip electrophoresis in microfluidic devices with advanced temperature control.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12652572     DOI: 10.1002/elps.200390031

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

Review 1.  Beyond gel electrophoresis: microfluidic separations, fluorescence burst analysis, and DNA stretching.

Authors:  Kevin D Dorfman; Scott B King; Daniel W Olson; Joel D P Thomas; Douglas R Tree
Journal:  Chem Rev       Date:  2012-11-12       Impact factor: 60.622

2.  Ligase detection reaction for the analysis of point mutations using free-solution conjugate electrophoresis in a polymer microfluidic device.

Authors:  Rondedrick Sinville; Jennifer Coyne; Robert J Meagher; Yu-Wei Cheng; Francis Barany; Annelise Barron; Steven A Soper
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

Review 3.  Effect of the matrix on DNA electrophoretic mobility.

Authors:  Nancy C Stellwagen; Earle Stellwagen
Journal:  J Chromatogr A       Date:  2008-12-06       Impact factor: 4.759

4.  Polyethylene Oxide (PEO) and Polyethylene Glycol (PEG) Polymer Sieving Matrix for RNA Capillary Electrophoresis.

Authors:  Yoshinori Yamaguchi; Zhenqing Li; Xifang Zhu; Chenchen Liu; Dawei Zhang; Xiaoming Dou
Journal:  PLoS One       Date:  2015-05-01       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.