Literature DB >> 12648646

Intraocular lens surfaces and their relationship to postoperative glare.

Jay C Erie1, Mark H Bandhauer.   

Abstract

PURPOSE: To estimate the potential for surface reflections in recently introduced intraocular lenses (IOLs) and to determine optic surface designs that will reduce surface reflections.
SETTING: Mayo Clinic, Rochester, Minnesota, USA.
METHODS: Surface-reflected glare in the unaccommodated human crystalline lens and in 6 IOLs (Bausch & Lomb SoFlex LI61U, Pharmacia CeeOn 911A, Allergan Sensar AR40, Bausch & Lomb Hydroview H60M, Alcon AcrySof MA60BM, Alcon AcrySof SA30AL) was examined in a physiologic eye model using the ZEMAX optical design program. Internal and external surface reflections were described and compared in terms of IOL surface reflectivity (%), area of the reflected glare image (mm(2)), and relative intensity of the reflected glare image.
RESULTS: Compared to surface reflections from the unaccommodated human lens with a corneal power of 43.0 diopters, all the IOLs increased the relative intensity of internal and external reflections by 3- to 36-fold except the MA60BM and the SA30AL, which increased the relative intensity of internal and external reflections by 730- to 1090-fold.
CONCLUSIONS: All the IOLs studied variably increased internal and external surface reflections when compared to the human crystalline lens. Surface reflections were minimized in optic designs with an anterior radius of curvature of approximately 17.0 mm or less.

Entities:  

Mesh:

Year:  2003        PMID: 12648646     DOI: 10.1016/s0886-3350(02)01442-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens.

Authors:  Yong Tang; Hui Song; Jing Chen; Xin Tang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Optical functional properties of the Boston Keratoprosthesis.

Authors:  Rony R Sayegh; Linda Avena Diaz; Fernando Vargas-Martín; Robert H Webb; Claes H Dohlman; Eli Peli
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-10-08       Impact factor: 4.799

3.  Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision.

Authors:  Ladan Espandar; Shameema Sikder; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2011-01-10

4.  Comparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract.

Authors:  Esra Ayhan Tuzcu; Kuddusi Erkilic; Betul Bulut; Nilufer Ilhan
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

Review 5.  Continuous Transitional Focus (CTF): A New Concept in Ophthalmic Surgery.

Authors:  Ramón Ruiz Mesa; Tiago Monteiro
Journal:  Ophthalmol Ther       Date:  2018-06-18

6.  Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens.

Authors:  Ya-Wen Guo; Jun Li; Hui Song; Xin Tang
Journal:  J Ophthalmol       Date:  2014-03-03       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.