Literature DB >> 12644801

Fracture toughness of nine flowable resin composites.

Esteban D Bonilla1, Mahrokh Yashar, Angelo A Caputo.   

Abstract

STATEMENT OF PROBLEM: Flowable composite is used in a variety of clinical applications; however, the capacity of these materials to resist crack propagation is not well understood.
PURPOSE: The purpose of this investigation was to compare the resistance to crack propagation of 9 flowable composites as measured by the fracture toughness.
MATERIAL AND METHODS: The composites studied include AeliteFlo, Crystal Essence, Flow-it, FloRestore, Permaflo, Revolution, Tetric Flow, VersaFlo, and Wave. Ten specimens of each composite were formed with a brass mold with a 3-mm preformed notch. The final dimensions of each specimen were 2 x 4.2 x 20 mm. All specimens were light-polymerized to manufacturer specifications and stored in air for 24 hours. The fracture toughness value, K(IC) (MNm(-3/2)), for each specimen was measured by use of a 3-point bending mode and a single-edge notched beam at a crosshead speed of 0.125 mm/min until fracture. The data were analyzed statistically by use of 1-way analysis of variance, t tests (P<.05), and regression analysis.
RESULTS: The flowable composites tested showed a spectrum of fracture toughness values ranging from 1.15 +/- 0.10 MNm(-3/2) for Wave to 1.65 +/- 0.13 MNm(-3/2) for Permaflo (significantly different, P<.05). The remaining materials formed 1 group with intermediate K(IC) values not different from each other (P>.05) but significantly different from Wave and Permaflo. Comparisons of fracture toughness to the filler content by volume of each composite revealed no correlation.
CONCLUSION: This in vitro study concluded that there was no significant difference among 7 of the 9 composites tested in their resistance to fracture. Permaflo showed the greatest resistance to crack propagation. There was no correlation between the filler content by volume and the fracture toughness of these flowable composites.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12644801     DOI: 10.1067/mpr.2003.33

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

Review 1.  Flowable Resin Composites: A Systematic Review and Clinical Considerations.

Authors:  Kusai Baroudi; Jean C Rodrigues
Journal:  J Clin Diagn Res       Date:  2015-06-01

2.  Accurate Critical Stress Intensity Factor Griffith Crack Theory Measurements by Numerical Techniques.

Authors:  Richard C Petersen
Journal:  Sampe J       Date:  2013       Impact factor: 0.182

3.  3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION.

Authors:  Richard Petersen; Perng-Ru Liu
Journal:  Sampe J       Date:  2016-05       Impact factor: 0.182

4.  Flowable composites for bonding orthodontic retainers.

Authors:  Sama Tabrizi; Elio Salemis; Serdar Usumez
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

5.  Mechanical evaluation of five flowable resin composites by the dynamic micro-indentation method.

Authors:  Satoshi Hirayama; Hirotoshi Iwai; Yasuhiro Tanimoto
Journal:  J Dent Biomech       Date:  2014-05-02

6.  Dual-functional porous and cisplatin-loaded polymethylmethacrylate cement for reconstruction of load-bearing bone defect kills bone tumor cells.

Authors:  Zhule Wang; Liebert Parreiras Nogueira; Håvard Jostein Haugen; Ingrid Cm Van Der Geest; Patricia Caetano de Almeida Rodrigues; Dennis Janssen; Thom Bitter; Jeroen J J P van den Beucken; Sander Cg Leeuwenburgh
Journal:  Bioact Mater       Date:  2021-12-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.