Femoral anteversion in children with cerebral palsy. Assessment with two and three-dimensional computed tomography scans.

Jon R Davids1, Amanda D Marshall, Edward R Blocker, Steven L Frick, Dawn W Blackhurst, Edward Skewes.   

Abstract

BACKGROUND: Assessment of femoral anteversion in children with cerebral palsy with two or three-dimensional computed tomography scans may be limited by both positional and anatomic variables. Three-dimensional computed tomography techniques are considered to be more accurate than two-dimensional imaging when the femur is not optimally positioned in the gantry or when the neck-shaft angle is increased.
METHODS: Computed tomography scanning was performed on a series of nine model femora with anteversion ranging from 20 degrees to 60 degrees and neck-shaft angles ranging from 120 degrees to 160 degrees. Each femoral model was scanned in two holding devices, the first of which held the femur in optimal alignment (normal model) and the second of which held the femur in flexion, adduction, and internal rotation (cerebral palsy model) relative to the gantry. Femoral anteversion was calculated for each model from two and three-dimensional computed tomography scans by four examiners on two separate occasions. The intraobserver and interobserver reliability, the accuracy, and the effect of increasing the neck-shaft angle on the accuracy of the measurements made on the two and three-dimensional scans of the normal and cerebral palsy models were then examined.
RESULTS: The mean differences in the measurements of femoral anteversion made by the same examiner (intraobserver reliability) were <2 degrees for the two-dimensional scans of the normal and cerebral palsy models and the three-dimensional scans of the normal models, and the mean difference was <4 degrees for the three-dimensional scans of the cerebral palsy models. The mean differences among examiners (interobserver reliability) were <3 degrees for the two-dimensional scans of the normal and cerebral palsy models and the three-dimensional scans of the normal models, and the mean difference was <6 degrees for the three-dimensional scans of the cerebral palsy models. The accuracy of the assessments of femoral anteversion of the normally aligned models was comparable between the two and three-dimensional scans. However, the three-dimensional assessment was significantly more accurate than the two-dimensional assessment for measurement of anteversion of the cerebral palsy models (p = 0.003). Accuracy within 5 degrees was comparable between the two and three-dimensional scans for measurement of the normally aligned models, with 86% of the two-dimensional measurements and 78% of the three-dimensional measurements falling within 5 degrees of the actual measurements. However, the accuracy within 5 degrees was significantly compromised when the models were placed in cerebral palsy alignment. Only 3% of the two-dimensional measurements and 14% of the three-dimensional measurements fell within 5 degrees of the actual measurements, with three-dimensional assessment being significantly better than two-dimensional assessment (p = 0.006). Increasing the neck-shaft angle did not significantly compromise the accuracy of measurement of femoral anteversion with either the two-dimensional or the three-dimensional technique (p > 0.05 for all comparisons).
CONCLUSIONS: When adequate alignment of the femur in the computed tomography scanner was possible, a simple two-dimensional technique exhibited excellent intraobserver and interobserver reliability and clinically acceptable accuracy within the relevant ranges of anatomic variability tested (neck-shaft angles of 120 degrees to 160 degrees and femoral anteversion of 20 degrees to 60 degrees). When optimal alignment of the femur in the scanner was not possible, neither two-dimensional nor three-dimensional techniques exhibited clinically acceptable accuracy for the measurement of femoral anteversion.

Entities:  

Mesh:

Year:  2003        PMID: 12637435

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

2.  A local reference frame for describing the proximal human femur: application in clinical settings.

Authors:  Milad Masjedi; Charison Tay; Simon J Harris; Justin P Cobb
Journal:  Skeletal Radiol       Date:  2013-12-18       Impact factor: 2.199

3.  Design and validation of automated femoral bone morphology measurements in cerebral palsy.

Authors:  Noyeol Park; Jehee Lee; Ki Hyuk Sung; Moon Seok Park; Seungbum Koo
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

4.  [Femoral nail osteosynthesis. Mechanical factors influencing the femoral antetorsion].

Authors:  M Citak; D Kendoff; M Citak; M J Gardner; M Oszwald; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-04       Impact factor: 1.000

5.  Determinants of Hip Displacement in Children With Cerebral Palsy.

Authors:  Chia Hsieh Chang; Ying Chih Wang; Pei Chi Ho; Ai Wen Hwang; Hsuan Kai Kao; Wei Chun Lee; Wen E Yang; Ken N Kuo
Journal:  Clin Orthop Relat Res       Date:  2015-08-20       Impact factor: 4.176

6.  Automated quantification of aortoaortic and aortoiliac angulation for computed tomographic angiography of abdominal aortic aneurysms before endovascular repair: preliminary study.

Authors:  Bhargav Raman; Raghav Raman; Sandy Napel; Geoffrey D Rubin
Journal:  J Vasc Interv Radiol       Date:  2010-10-08       Impact factor: 3.464

7.  Radiographic quantification of dynamic hip screw migration.

Authors:  Laurent Audigé; Flurin Cagienard; Christoph Martin Sprecher; Norbert Suhm; Marc Andreas Müller
Journal:  Int Orthop       Date:  2013-10-22       Impact factor: 3.075

8.  Determination of Femoral Neck Angle and Torsion Angle Utilizing a Novel Three-Dimensional Modeling and Analytical Technology Based on CT Datasets.

Authors:  Maximilian J Hartel; Andreas Petersik; Anne Schmidt; Daniel Kendoff; Jakob Nüchtern; Johannes M Rueger; Wolfgang Lehmann; Lars G Grossterlinden
Journal:  PLoS One       Date:  2016-03-02       Impact factor: 3.240

9.  Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion.

Authors:  Dong-Mei Sun; Shi-Nong Pan; En-Bo Wang; Li-Qiang Zheng; Wen-Li Guo; Xi-Hu Fu
Journal:  Chin Med J (Engl)       Date:  2016-07-05       Impact factor: 2.628

10.  Progression of Hip Displacement during Radiographic Surveillance in Patients with Cerebral Palsy.

Authors:  Jae Young Park; Young Choi; Byung Chae Cho; Sang Young Moon; Chin Youb Chung; Kyoung Min Lee; Ki Hyuk Sung; Soon-Sun Kwon; Moon Seok Park
Journal:  J Korean Med Sci       Date:  2016-05-19       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.