Literature DB >> 12636190

Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days.

Ann M Diskin1, Patrik Spanel, David Smith.   

Abstract

A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three consecutive breath exhalations were carried out using selected ion flow tube mass spectrometry (SIFT-MS) on line to the instrument. Sufficient data were obtained to allow meaningful concentration distributions to be obtained for ammonia, acetone, isoprene and ethanol. These showed that the ammonia, acetone and isoprene concentrations exhibited sensibly normal distributions, with coefficients of variation of typically 0.3. Obvious and statistically significant (p < 0.01) differences are apparent in the mean concentrations of these metabolites between the five individuals. The acetaldehyde concentrations were relatively low and close to the instrument detection limit, and the differences between the mean concentrations of the five subjects were not statistically significant (p = 0.4), so distributions were not obtained. The mean concentrations, in parts per billion (ppb), of each metabolite range amongst the five subjects are as follows: ammonia, 422-2389: acetone, 293-870; isoprene, 55-121; ethanol, 27-153; acetaldehyde, 2-5. There are no obvious patterns in the distributions of these particular metabolites for these individuals, except that the ammonia levels were greatest in the breath of the two oldest subjects.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12636190     DOI: 10.1088/0967-3334/24/1/308

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  28 in total

Review 1.  Advances in electronic-nose technologies developed for biomedical applications.

Authors:  Alphus D Wilson; Manuela Baietto
Journal:  Sensors (Basel)       Date:  2011-01-19       Impact factor: 3.576

2.  Impact of airway gas exchange on the multiple inert gas elimination technique: theory.

Authors:  Joseph C Anderson; Michael P Hlastala
Journal:  Ann Biomed Eng       Date:  2010-03       Impact factor: 3.934

3.  Orthogonal gas sensor arrays by chemoresistive material design.

Authors:  Nicolay J Pineau; Julia F Kompalla; Andreas T Güntner; Sotiris E Pratsinis
Journal:  Mikrochim Acta       Date:  2018-11-28       Impact factor: 5.833

4.  Dependence of exhaled breath composition on exogenous factors, smoking habits and exposure to air pollutants.

Authors:  W Filipiak; V Ruzsanyi; P Mochalski; A Filipiak; A Bajtarevic; C Ager; H Denz; W Hilbe; H Jamnig; M Hackl; A Dzien; A Amann
Journal:  J Breath Res       Date:  2012-09       Impact factor: 3.262

5.  Online sample conditioning for portable breath analyzers.

Authors:  Amlendu Prabhakar; Rodrigo A Iglesias; Xiaonan Shan; Xiaojun Xian; Lihua Zhang; Francis Tsow; Erica S Forzani; Nongjian Tao
Journal:  Anal Chem       Date:  2012-08-08       Impact factor: 6.986

6.  Toward portable breath acetone analysis for diabetes detection.

Authors:  Marco Righettoni; Antonio Tricoli
Journal:  J Breath Res       Date:  2011-08-09       Impact factor: 3.262

Review 7.  Emerging Theranostic Nanomaterials in Diabetes and Its Complications.

Authors:  Yuntao Liu; Siqi Zeng; Wei Ji; Huan Yao; Lin Lin; Haiying Cui; Hélder A Santos; Guoqing Pan
Journal:  Adv Sci (Weinh)       Date:  2021-11-25       Impact factor: 16.806

8.  Halitosis: a new definition and classification.

Authors:  M Aydin; C N Harvey-Woodworth
Journal:  Br Dent J       Date:  2014-07-11       Impact factor: 1.626

9.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

10.  Breath acetone monitoring by portable Si:WO3 gas sensors.

Authors:  Marco Righettoni; Antonio Tricoli; Samuel Gass; Alex Schmid; Anton Amann; Sotiris E Pratsinis
Journal:  Anal Chim Acta       Date:  2012-06-12       Impact factor: 6.558

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.