Literature DB >> 12632129

Use of head-mounted display in transanal endoscopic microsurgery.

J J M van Koesveld1, G W M Tetteroo, E J R de Graaf.   

Abstract

BACKGROUND: Head-mounted display (HMD) decreases the forced adjustments of position and eyes in endoscopic surgery. During transanal endoscopic microsurgery (TEM), these adjustments might even be greater because of the direct viewing technique. We investigated the feasibility of HMD in TEM.
METHODS: Head-mounted display is a helmet with two built-in displays. The stereoscopic endoscope (with two separate lens systems) provides separate images at each display. During TEM, standard stereoscopic optic and HMD were alternated.
RESULTS: Use of HMD was possible after construction of a special device. The helmet was comfortable to wear, and the peripheral view was adequate. The operator's position was upright and relaxed. The range and depth of vision seemed comparable with those of the standard stereoscopic optic. The quality of the displays in the helmet is limited.
CONCLUSIONS: Head-mounted display is feasible in TEM. It enables a more relaxed position and view on the operative field. The quality of the display in the helmet requires improvement.

Mesh:

Year:  2003        PMID: 12632129     DOI: 10.1007/s00464-002-9067-4

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  11 in total

1.  Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue.

Authors:  S K Maithel; L Villegas; N Stylopoulos; S Dawson; D B Jones
Journal:  Surg Endosc       Date:  2004-12-23       Impact factor: 4.584

2.  Technologies and solutions for data display in the operating room.

Authors:  Noemi Bitterman
Journal:  J Clin Monit Comput       Date:  2006-05-11       Impact factor: 2.502

Review 3.  A review of wearable technology in medicine.

Authors:  Mohammed H Iqbal; Abdullatif Aydin; Oliver Brunckhorst; Prokar Dasgupta; Kamran Ahmed
Journal:  J R Soc Med       Date:  2016-10       Impact factor: 5.344

4.  Comparison of optical see-through head-mounted displays for surgical interventions with object-anchored 2D-display.

Authors:  Long Qian; Alexander Barthel; Alex Johnson; Greg Osgood; Peter Kazanzides; Nassir Navab; Bernhard Fuerst
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-25       Impact factor: 2.924

5.  Ultracision Harmonic Scalpel and multifunctional tem400 instrument complement in transanal endoscopic microsurgery: a prospective study.

Authors:  I D Ayodeji; W C J Hop; G W M Tetteroo; H J Bonjer; E J R de Graaf
Journal:  Surg Endosc       Date:  2004-10-26       Impact factor: 4.584

6.  Compact Smartphone-Based Laser Speckle Contrast Imaging Endoscope Device for Point-of-Care Blood Flow Monitoring.

Authors:  Youngkyu Kim; Woo June Choi; Jungmin Oh; Jun Ki Kim
Journal:  Biosensors (Basel)       Date:  2022-06-09

Review 7.  Transanal endoscopic microsurgery.

Authors:  M Morino; A Arezzo; M E Allaix
Journal:  Tech Coloproctol       Date:  2013-01-12       Impact factor: 3.781

8.  Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study.

Authors:  Jung Kweon Bae; Andrey Vavilin; Joon S You; Hyeongeun Kim; Seon Young Ryu; Jeong Hun Jang; Woonggyu Jung
Journal:  JMIR Mhealth Uhealth       Date:  2017-07-27       Impact factor: 4.773

9.  A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

Authors:  Xinghua Xu; Yi Zheng; Shujing Yao; Guochen Sun; Bainan Xu; Xiaolei Chen
Journal:  Brain Behav       Date:  2017-12-14       Impact factor: 2.708

10.  [Not Available].

Authors:  James G Bittner; Christopher A Hathaway; James A Brown
Journal:  J Minim Access Surg       Date:  2008-04       Impact factor: 1.407

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.