BACKGROUND: The Genius single-pass batch system for hemodialysis contains a closed reservoir and dialysate circuit of 75 L dialysate. The unused dialysate is withdrawn at the top of the reservoir and the spent fluid is reintroduced into the container at the bottom. Although it has been claimed that both fractions remain unmixed during the dialysis session, no direct proof of this assumption has yet been provided. In the present study, we investigated whether contamination of the unused dialysate with uremic solutes occurred and at which time point it began. Two different dialysate temperatures were compared. METHODS: Ten chronic hemodialysis patients were dialyzed twice with the Genius system, with dialysate prepared at 37 degrees C and 38.5 degrees C, respectively. The sessions lasted 270 minutes with blood/dialysate flow set at 300 mL/min. Dialysate was sampled at 5, 60, 180, 210, 225, 230, 235, 240, 255, and 270 minutes both from the inlet and outlet dialysate line and blood was sampled from the arterial line predialysis, after 4 hours, and postdialysis. All samples were tested for osmolality, urea, creatinine, p-cresol, hippuric acid, and indoxyl sulfate. RESULTS: Uremic solutes appeared in the inlet dialysate line between 3 hours 50 minutes and 4 hours 10 minutes after the start of dialysis, corresponding to 68.6 and 74.7 L spent dialysate, respectively (37 degrees C vs. 38.5 degrees C; P = NS). No difference in the amount of removed solutes and in the serum levels was observed between 37 degrees C and 38.5 degrees C. A Kt/V of 1.17 +/- 0.20 and 1.18 +/- 0.26, respectively, was reached with the 37 degrees C and 38.5 degrees C dialysate temperature (P = NS). CONCLUSION: Contamination with uremic solutes occurred at the dialysate inlet only near the end of the session when small quantities of fresh dialysate were left in the container. Differences in dialysate temperature did not result in a different separation between used and unused dialysate, or in differences in removal of toxins or Kt/V.
BACKGROUND: The Genius single-pass batch system for hemodialysis contains a closed reservoir and dialysate circuit of 75 L dialysate. The unused dialysate is withdrawn at the top of the reservoir and the spent fluid is reintroduced into the container at the bottom. Although it has been claimed that both fractions remain unmixed during the dialysis session, no direct proof of this assumption has yet been provided. In the present study, we investigated whether contamination of the unused dialysate with uremic solutes occurred and at which time point it began. Two different dialysate temperatures were compared. METHODS: Ten chronic hemodialysis patients were dialyzed twice with the Genius system, with dialysate prepared at 37 degrees C and 38.5 degrees C, respectively. The sessions lasted 270 minutes with blood/dialysate flow set at 300 mL/min. Dialysate was sampled at 5, 60, 180, 210, 225, 230, 235, 240, 255, and 270 minutes both from the inlet and outlet dialysate line and blood was sampled from the arterial line predialysis, after 4 hours, and postdialysis. All samples were tested for osmolality, urea, creatinine, p-cresol, hippuric acid, and indoxyl sulfate. RESULTS: Uremic solutes appeared in the inlet dialysate line between 3 hours 50 minutes and 4 hours 10 minutes after the start of dialysis, corresponding to 68.6 and 74.7 L spent dialysate, respectively (37 degrees C vs. 38.5 degrees C; P = NS). No difference in the amount of removed solutes and in the serum levels was observed between 37 degrees C and 38.5 degrees C. A Kt/V of 1.17 +/- 0.20 and 1.18 +/- 0.26, respectively, was reached with the 37 degrees C and 38.5 degrees C dialysate temperature (P = NS). CONCLUSION: Contamination with uremic solutes occurred at the dialysate inlet only near the end of the session when small quantities of fresh dialysate were left in the container. Differences in dialysate temperature did not result in a different separation between used and unused dialysate, or in differences in removal of toxins or Kt/V.
Authors: Renato A Caires; Regina C R M Abdulkader; Verônica T Costa E Silva; Gillene S Ferreira; Emmanuel A Burdmann; Luis Yu; Etienne Macedo Journal: J Nephrol Date: 2015-08-23 Impact factor: 3.902
Authors: Stefanie Swoboda; Michael C Ober; Christoph Lichtenstern; Soundos Saleh; Vedat Schwenger; Hans-Günther Sonntag; Walter Emil Haefeli; Georg Hempel; Torsten Hoppe-Tichy; Markus A Weigand Journal: Eur J Clin Pharmacol Date: 2009-12-16 Impact factor: 2.953
Authors: Vedat Schwenger; Markus A Weigand; Oskar Hoffmann; Ralf Dikow; Lars P Kihm; Jörg Seckinger; Nexhat Miftari; Matthias Schaier; Stefan Hofer; Caroline Haar; Peter P Nawroth; Martin Zeier; Eike Martin; Christian Morath Journal: Crit Care Date: 2012-07-27 Impact factor: 9.097
Authors: Anke Dahlmann; Kathrin Dörfelt; Florian Eicher; Peter Linz; Christoph Kopp; Irina Mössinger; Stephan Horn; Beatrix Büschges-Seraphin; Peter Wabel; Matthias Hammon; Alexander Cavallaro; Kai-Uwe Eckardt; Peter Kotanko; Nathan W Levin; Bernd Johannes; Michael Uder; Friedrich C Luft; Dominik N Müller; Jens M Titze Journal: Kidney Int Date: 2014-08-06 Impact factor: 10.612