Literature DB >> 12628888

Clinical utility of blood cultures drawn from central vein catheters and peripheral venipuncture in critically ill medical patients.

Michelle Beutz1, Glenda Sherman, Jennie Mayfield, Victoria J Fraser, Marin H Kollef.   

Abstract

STUDY
OBJECTIVE: To determine the sensitivity, specificity, and positive and negative predictive values of blood cultures obtained through a central vein catheter compared with peripheral venipuncture.
DESIGN: Prospective cohort study.
SETTING: A medical ICU (19 beds) from a university-affiliated urban teaching hospital. PATIENTS: Between February 2001 and October 2001, 300 paired blood culture specimens were obtained from 119 patients (2.52 paired cultures per patient). INTERVENTION: Prospective patient surveillance and data collection.
MEASUREMENTS AND MAIN RESULTS: Thirty-four paired culture results (11.3%; 95% confidence interval, 7.8 to 14.8%) were accepted as true-positives representing a true bacteremia. The sensitivity of catheter-drawn and peripheral venipuncture samples was 82.4% and 64.7%, respectively, and specificity was 92.5% and 95.9%. The positive predictive value was 58.3% for catheter-drawn samples and 66.7% for peripheral venipuncture samples, and the respective negative predictive values were 97.6% and 95.5%.
CONCLUSIONS: In critically ill medical patients, the negative predictive value of blood samples obtained by catheter draw or peripheral venipuncture for suspected bloodstream infection is good. However, the sensitivity of blood samples obtained by either catheter draw or peripheral venipuncture alone is not adequate to recommend the elimination of blood samples obtained from the other site. Clinicians should also be aware that additional blood samples may be necessary when interpreting positive blood culture results for common skin or central vein catheter contaminants.

Entities:  

Mesh:

Year:  2003        PMID: 12628888     DOI: 10.1378/chest.123.3.854

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  12 in total

Review 1.  Updated review of blood culture contamination.

Authors:  Keri K Hall; Jason A Lyman
Journal:  Clin Microbiol Rev       Date:  2006-10       Impact factor: 26.132

2.  Discrepant results from sampling different lumens of multilumen catheters: the case for sampling all lumens.

Authors:  J Cuellar-Rodriguez; D Connor; P Murray; J Gea-Banacloche
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-12-03       Impact factor: 3.267

3.  Species-driven interpretation guidelines in case of a single-sampling strategy for blood culture.

Authors:  D Leyssene; S Gardes; P Vilquin; J-P Flandrois; G Carret; B Lamy
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-18       Impact factor: 3.267

Review 4.  Effectiveness of practices to reduce blood culture contamination: a Laboratory Medicine Best Practices systematic review and meta-analysis.

Authors:  Susan R Snyder; Alessandra M Favoretto; Rich Ann Baetz; James H Derzon; Bereneice M Madison; Diana Mass; Colleen S Shaw; Christopher D Layfield; Robert H Christenson; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-06-16       Impact factor: 3.281

5.  Blood drawn through valved catheter hub connectors carries a significant risk of contamination.

Authors:  R J Sherertz; T B Karchmer; E Palavecino; W Bischoff
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-05-01       Impact factor: 3.267

6.  Utility of peripheral blood cultures in bacteremic pediatric cancer patients with a central line.

Authors:  Katrin Scheinemann; Marie-Chantal Ethier; L Lee Dupuis; Susan E Richardson; John Doyle; Upton Allen; Lillian Sung
Journal:  Support Care Cancer       Date:  2009-08-29       Impact factor: 3.603

Review 7.  Utility of peripheral blood cultures in patients with cancer and suspected blood stream infections: a systematic review.

Authors:  Laura Rodríguez; Marie-Chantal Ethier; Bob Phillips; Thomas Lehrnbecher; John Doyle; Lillian Sung
Journal:  Support Care Cancer       Date:  2012-04-29       Impact factor: 3.603

8.  Diagnostic utility of broad range bacterial 16S rRNA gene PCR with degradation of human and free bacterial DNA in bloodstream infection is more sensitive than an in-house developed PCR without degradation of human and free bacterial DNA.

Authors:  Petra Rogina; Miha Skvarc; David Stubljar; Romina Kofol; Achim Kaasch
Journal:  Mediators Inflamm       Date:  2014-07-09       Impact factor: 4.711

9.  Nosocomial bloodstream infection and clinical sepsis.

Authors:  Stéphane Hugonnet; Hugo Sax; Philippe Eggimann; Jean-Claude Chevrolet; Didier Pittet
Journal:  Emerg Infect Dis       Date:  2004-01       Impact factor: 6.883

10.  A prospective multicenter evaluation of direct molecular detection of blood stream infection from a clinical perspective.

Authors:  A E Nieman; P H M Savelkoul; A Beishuizen; B Henrich; B Lamik; C R MacKenzie; D Kindgen-Milles; A Helmers; C Diaz; S G Sakka; R P Schade
Journal:  BMC Infect Dis       Date:  2016-06-30       Impact factor: 3.090