Transvenous defibrillation leads: high incidence of failure during long-term follow-up.

Uwe Dorwarth1, Bernhard Frey, Martin Dugas, Tomas Matis, Michael Fiek, Michael Schmoeckel, Thomas Remp, Ilka Durchlaub, Andrea Gerth, Gerhard Steinbeck, Ellen Hoffmann.   

Abstract

INTRODUCTION: Patients with implantable cardioverter defibrillators (ICD) critically depend on correct functioning of their system. The aim of this study was to determine the incidence and clinical presentation of transvenous ICD lead failures during long-term follow-up. METHODS AND
RESULTS: The study group consisted of 261 consecutive patients who received Medtronic right ventricular polyurethane transvenous leads (models 6884, 6966, 6936) between 1990 and 1998 as part of an abdominal (n = 70) or pectoral (n = 191) ICD system. During mean follow-up of 4.0 +/- 2.6 years, 31 patients (12%) developed a lead-related sensing failure with oversensing of artifacts. All failures except two were compatible with an insulation defect and occurred late after ICD placement (6.0 +/- 1.8 years after implant). Lead survival decreased from 98% at 4-year follow-up to only 62% at 8-year follow-up. Lead survival was not related to patient age, sex, venous lead implantation route, or device implantation site. In 26 (87%) of 31 patients, a sensing defect resulted in inappropriate detection of ventricular fibrillation and subsequent delivery of 3 +/- 3 (range 1-11) inappropriate shocks in 19 (61%) of 31 patients. Device interrogation showed artifacts classified as nonsustained ventricular tachycardia in 21 patients, 40 +/- 43 days before clinically relevant failure of the system. One patient with a subclavian crush syndrome required resuscitation because of undersensing of true ventricular fibrillation.
CONCLUSION: Transvenous polyurethane ICD leads showed a high rate of lead insulation failure late after implantation with frequent inappropriate shock deliveries. Close follow-up is mandatory in patients with these leads. Automated device control features with patient alert function integrated into new devices may contribute to early detection of lead failure.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12625608     DOI: 10.1046/j.1540-8167.2003.02305.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  12 in total

Review 1.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

2.  Complications and lead extraction in cardiac pacing and defibrillation.

Authors:  F Bracke
Journal:  Neth Heart J       Date:  2008-10       Impact factor: 2.380

Review 3.  Subcutaneous chronic implantable defibrillation systems in humans.

Authors:  Riccardo Cappato; Warren M Smith; Margaret A Hood; Ian G Crozier; Luc Jordaens; Stefan G Spitzer; Andrey V Ardashev; Lucas Boersma; Pierpaolo Lupo; Andrew A Grace; Gust H Bardy
Journal:  J Interv Card Electrophysiol       Date:  2012-03-17       Impact factor: 1.900

4.  Riata lead failure with normal electrical lead parameters and normal fluoroscopic appearance.

Authors:  Umashankar Lakshmanadoss; David Lahoda; Pramod Deshmukh
Journal:  J Interv Card Electrophysiol       Date:  2012-10-19       Impact factor: 1.900

Review 5.  [Home Monitoring with implantable ICD--a diagnostic innovation?].

Authors:  W Jung; R Birkemeyer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-09

Review 6.  Complications in Device Therapy: Spectrum, Prevalence, and Management.

Authors:  J Llewellyn; D Garner; A Rao
Journal:  Curr Heart Fail Rep       Date:  2022-08-06

Review 7.  Pacemaker and ICD leads: strategies for long-term management.

Authors:  P Peter Borek; Bruce L Wilkoff
Journal:  J Interv Card Electrophysiol       Date:  2008-04-08       Impact factor: 1.900

8.  Evaluation of subcutaneous implantable cardioverter-defibrillator performance in patients with ion channelopathies from the EFFORTLESS cohort and comparison with a meta-analysis of transvenous ICD outcomes.

Authors:  Pier D Lambiase; Lars Eckardt; Dominic A Theuns; Timothy R Betts; Andreas L Kyriacou; Elizabeth Duffy; Reinoud Knops
Journal:  Heart Rhythm O2       Date:  2020-10-28

9.  Generator and lead-related complications of implantable cardioverter defibrillators.

Authors:  Ahmad Yaminisharif; Nader Soofizadeh; Akbar Shafiee; Ali Kazemisaeid; Arash Jalali; Ali Vasheghani-Farahani
Journal:  Int Cardiovasc Res J       Date:  2014-04-01

10.  A simple, wide bandwidth, biopotential amplifier to record pacemaker pulse waveform.

Authors:  Paolo Bifulco; Gaetano Dario Gargiulo; Maria Romano; Mario Cesarelli
Journal:  Med Devices (Auckl)       Date:  2016-09-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.