BACKGROUND: Increase in the number of patients treated with Implantable Cardioverter Defibrillator (ICD) requests more attention regarding its complications. OBJECTIVES: This study aimed to assess the generator- and lead-related complications at implantation and during follow-up in the patients who were treated with ICD for primary and secondary prevention reasons. METHODS: We retrospectively reviewed 255 consecutive patients who underwent transvenous ICD implantation for the first time in a 7-year period and were followed-up for 3 years at Tehran Heart Center. The personal and clinical data of the patients as well as specific data on the ICD implantation were retrieved. The frequency of each of the complications was reported and the study variables were compared between the patients with and without complications using Student's t-test and chi-square test where appropriate. P values less than 0.05 were considered as statistically significant. RESULTS: Out of a total of 525 implanted leads and 255 implanted devices in 255 patients (mean age = 62.57 ± 13.50 years; male = 196 [76.9%]), complications leading to generator or lead replacement occurred in 32 patients (12.5%). The results revealed no significant difference between the patients with and without complications regarding gender and age (P = 0.206 and P = 0.824, respectively). Also, no significant difference was found between the two groups concerning the ejection fraction (P = 0.271). Lead fracture was the most frequent lead-related complication and was observed in 17 patients (6.6%). Besides, it was mainly observed in the RV leads. Generator-related complications leading to generator replacement were observed in 2 patients (0.7%). CONCLUSIONS: Despite considerable improvements in the ICD technology, the rate of the ICD complications leading to device replacement and surgical revision, especially those related to the leads, is still clinically important.
BACKGROUND: Increase in the number of patients treated with Implantable Cardioverter Defibrillator (ICD) requests more attention regarding its complications. OBJECTIVES: This study aimed to assess the generator- and lead-related complications at implantation and during follow-up in the patients who were treated with ICD for primary and secondary prevention reasons. METHODS: We retrospectively reviewed 255 consecutive patients who underwent transvenous ICD implantation for the first time in a 7-year period and were followed-up for 3 years at Tehran Heart Center. The personal and clinical data of the patients as well as specific data on the ICD implantation were retrieved. The frequency of each of the complications was reported and the study variables were compared between the patients with and without complications using Student's t-test and chi-square test where appropriate. P values less than 0.05 were considered as statistically significant. RESULTS: Out of a total of 525 implanted leads and 255 implanted devices in 255 patients (mean age = 62.57 ± 13.50 years; male = 196 [76.9%]), complications leading to generator or lead replacement occurred in 32 patients (12.5%). The results revealed no significant difference between the patients with and without complications regarding gender and age (P = 0.206 and P = 0.824, respectively). Also, no significant difference was found between the two groups concerning the ejection fraction (P = 0.271). Lead fracture was the most frequent lead-related complication and was observed in 17 patients (6.6%). Besides, it was mainly observed in the RV leads. Generator-related complications leading to generator replacement were observed in 2 patients (0.7%). CONCLUSIONS: Despite considerable improvements in the ICD technology, the rate of the ICD complications leading to device replacement and surgical revision, especially those related to the leads, is still clinically important.
Authors: Andreas Goette; Francesco Cantu; Lieselot van Erven; Peter Geelen; Franck Halimi; Jose L Merino; John M Morgan Journal: Europace Date: 2008-11-11 Impact factor: 5.214
Authors: Matthew R Reynolds; David J Cohen; Aaron D Kugelmass; Phillip P Brown; Edmund R Becker; Steven D Culler; April W Simon Journal: J Am Coll Cardiol Date: 2006-05-30 Impact factor: 24.094
Authors: S J Connolly; M Gent; R S Roberts; P Dorian; D Roy; R S Sheldon; L B Mitchell; M S Green; G J Klein; B O'Brien Journal: Circulation Date: 2000-03-21 Impact factor: 29.690
Authors: Wolfram Grimm; Astrid Stula; Julia Sharkova; Peter Alter; Bernhard Maisch Journal: Pacing Clin Electrophysiol Date: 2007-01 Impact factor: 1.976
Authors: Gabor Z Duray; Joern Schmitt; Sule Cicek-Hartvig; Stefan H Hohnloser; Carsten W Israel Journal: Europace Date: 2008-12-02 Impact factor: 5.214
Authors: Robert G Hauser; Linda M Kallinen; Adrian K Almquist; Charles C Gornick; William T Katsiyiannis Journal: Heart Rhythm Date: 2007-04-10 Impact factor: 6.343
Authors: Amir Ali Rahsepar; Jeremy D Collins; Bradley P Knight; KyungPyo Hong; James C Carr; Daniel Kim Journal: Clin Imaging Date: 2018-05-04 Impact factor: 1.605