A biplanar reconstruction method based on 2D and 3D contours: application to the distal femur.

S Laporte1, W Skalli, J A de Guise, F Lavaste, D Mitton.   

Abstract

A three-dimensional (3D) reconstruction algorithm based on contours identification from biplanar radiographs is presented. It requires, as technical prerequisites, a method to calibrate the biplanar radiographic environment and a surface generic object (anatomic atlas model) representing the structure to be reconstructed. The reconstruction steps consist of: the definition of anatomical regions, the identification of 2D contours associated to these regions, the calculation of 3D contours and projection onto the radiographs, the associations between points of the X-rays contours and points of the projected 3D contours, the optimization of the initial solution and the optimized object deformation to minimize the distance between X-rays contours and projected 3D contours. The evaluation was performed on 8 distal femurs comparing the 3D models obtained to CT-scan reconstructions. Mean error for each distal femur was 1 mm.

Entities:  

Mesh:

Year:  2003        PMID: 12623432     DOI: 10.1080/1025584031000065956

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  18 in total

1.  Fast 3D reconstruction of the rib cage from biplanar radiographs.

Authors:  E Jolivet; B Sandoz; S Laporte; D Mitton; W Skalli
Journal:  Med Biol Eng Comput       Date:  2010-04-23       Impact factor: 2.602

2.  Measuring physiological and pathological femoral anteversion using a biplanar low-dose X-ray system: validity, reliability, and discriminative ability in cerebral palsy.

Authors:  Matthias Thépaut; Sylvain Brochard; Julien Leboucher; Mathieu Lempereur; Eric Stindel; Valentin Tissot; Bhushan S Borotikar
Journal:  Skeletal Radiol       Date:  2015-11-27       Impact factor: 2.199

3.  Three-dimensional X-ray absorptiometry (3D-XA): a method for reconstruction of human bones using a dual X-ray absorptiometry device.

Authors:  S Kolta; A Le Bras; D Mitton; V Bousson; J A de Guise; J Fechtenbaum; J D Laredo; C Roux; W Skalli
Journal:  Osteoporos Int       Date:  2004-12-14       Impact factor: 4.507

4.  Personalized models of bones based on radiographic photogrammetry.

Authors:  E Berthonnaud; R Hilmi; J Dimnet
Journal:  Surg Radiol Anat       Date:  2009-02-04       Impact factor: 1.246

5.  Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity.

Authors:  A Baudoin; W Skalli; J A de Guise; D Mitton
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

6.  Axial plane dissimilarities of two identical Lenke-type 6C scoliosis cases visualized and analyzed by vertebral vectors.

Authors:  Tamás S Illés; Máté Burkus; Szabolcs Somoskeőy; Fabien Lauer; Francois Lavaste; Jean F Dubousset
Journal:  Eur Spine J       Date:  2018-04-06       Impact factor: 3.134

7.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

8.  Generation of a 3D proximal femur shape from a single projection 2D radiographic image.

Authors:  C M Langton; S Pisharody; J H Keyak
Journal:  Osteoporos Int       Date:  2008-06-19       Impact factor: 4.507

9.  Prediction of in vivo knee joint kinematics using a combined dual fluoroscopy imaging and statistical shape modeling technique.

Authors:  Jing-Sheng Li; Tsung-Yuan Tsai; Shaobai Wang; Pingyue Li; Young-Min Kwon; Andrew Freiberg; Harry E Rubash; Guoan Li
Journal:  J Biomech Eng       Date:  2014-12       Impact factor: 2.097

Review 10.  The horizontal plane appearances of scoliosis: what information can be obtained from top-view images?

Authors:  Tamás S Illés; Máté Burkus; Szabolcs Somoskeőy; Fabien Lauer; Francois Lavaste; Jean F Dubousset
Journal:  Int Orthop       Date:  2017-08-11       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.