Literature DB >> 12617356

Evaluation of a semiautomatic 3D fusion technique applied to molecular imaging and MRI brain/frame volume data sets.

R J T Gorniak1, E L Kramer, G Q Maguire, M E Noz, C J Schettino, M P Zeleznik.   

Abstract

A generally applicable 3D fusion method was evaluated using molecular imaging and MRI volumetric data sets from 15 brain tumor patients with stereotactic frames attached to their skull. Point pairs, placed on the frame only, were chosen, polynomial warping coefficients were generated to map voxels from one coordinate space to the other. The MRI frame was considered the reference structure and the standard for "correct" registration. An ANOVA test (p > 0.05) confirmed the point pair choice to be consistent. The 95% confidence interval for the t-test showed the measured distance difference between the registered volumes was within one MRI voxel. A further experiment was conducted to independently evaluate the brain registration based on testing for consistency of randomly selected interior/exterior points. A t-test result (p < 0.05) showed that the consistency (i.e., both interior or both exterior) before and after volume registration were significantly different. This fusion method may be a viable alternative when other methods fail.

Entities:  

Mesh:

Year:  2003        PMID: 12617356     DOI: 10.1023/a:1021860910856

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  14 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  A versatile functional-anatomic image fusion method for volume data sets.

Authors:  M E Noz; G Q Maguire; M P Zeleznik; E L Kramer; F Mahmoud; J Crafoord
Journal:  J Med Syst       Date:  2001-10       Impact factor: 4.460

3.  Landmark-based elastic registration using approximating thin-plate splines.

Authors:  K Rohr; H S Stiehl; R Sprengel; T M Buzug; J Weese; M H Kuhn
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

4.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

Authors:  C R Meyer; J L Boes; B Kim; P H Bland; K R Zasadny; P V Kison; K Koral; K A Frey; R L Wahl
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

5.  Automated 3-D registration of MR and CT images of the head.

Authors:  C Studholme; D L Hill; D J Hawkes
Journal:  Med Image Anal       Date:  1996-06       Impact factor: 8.545

6.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures.

Authors:  C Studholme; D L Hill; D J Hawkes
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

7.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

8.  CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings.

Authors:  E L Kramer; M E Noz; J J Sanger; A J Megibow; G Q Maguire
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

9.  Accurate three-dimensional registration of CT, PET, and/or MR images of the brain.

Authors:  C A Pelizzari; G T Chen; D R Spelbring; R R Weichselbaum; C T Chen
Journal:  J Comput Assist Tomogr       Date:  1989 Jan-Feb       Impact factor: 1.826

10.  A generalized pencil beam algorithm for optimization of radiation therapy.

Authors:  A Gustafsson; B K Lind; A Brahme
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

View more
  12 in total

1.  3D surface measurement for medical application--technical comparison of two established industrial surface scanning systems.

Authors:  K Schwenzer-Zimmerer; J Haberstok; L Kovacs; B I Boerner; N Schwenzer; P Juergens; H F Zeihofer; C Holberg
Journal:  J Med Syst       Date:  2008-02       Impact factor: 4.460

2.  Performance Evaluation of Color Models in the Fusion of Functional and Anatomical Images.

Authors:  Padma Ganasala; Vinod Kumar; A D Prasad
Journal:  J Med Syst       Date:  2016-04-01       Impact factor: 4.460

3.  Enhancing the utility of prostascint SPECT scans for patient management.

Authors:  Marilyn E Noz; Grace Chung; Benjamin Y Lee; Gerald Q Maguire; J Keith DeWyngaert; Jay V Doshi; Elissa L Kramer; Antoinette D Murphy-Walcott; Michael P Zeleznik; Noeun G Kwak
Journal:  J Med Syst       Date:  2006-04       Impact factor: 4.460

4.  Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at three-dimensional angiography.

Authors:  Tamer Hassan; Eugene V Timofeev; Tsutomu Saito; Hiroaki Shimizu; Masayuki Ezura; Teiji Tominaga; Akira Takahashi; Kazuyoshi Takayama
Journal:  AJNR Am J Neuroradiol       Date:  2004-09       Impact factor: 3.825

5.  Validation of a 3D CT method for measurement of linear wear of acetabular cups.

Authors:  Anneli Jedenmalm; Fritjof Nilsson; Marilyn E Noz; Douglas D Green; Ulf W Gedde; Ian C Clarke; Andreas Stark; Gerald Q Maguire; Michael P Zeleznik; Henrik Olivecrona
Journal:  Acta Orthop       Date:  2011-02-01       Impact factor: 3.717

6.  Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences.

Authors:  Henrik Lundblad; Gerald Q Maguire; Charlotte Karlsson-Thur; Cathrine Jonsson; Marilyn E Noz; Michael P Zeleznik; Hans Jacobsson; Lars Weidenhielm
Journal:  Biomed Res Int       Date:  2015-09-07       Impact factor: 3.411

7.  Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

Authors:  Cyrus Brodén; Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Olof Sköldenberg
Journal:  Biomed Res Int       Date:  2016-07-10       Impact factor: 3.411

8.  A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients.

Authors:  Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Uldis Kesteris; Lars Weidenhielm
Journal:  J Orthop Surg Res       Date:  2016-02-24       Impact factor: 2.359

9.  A new automated way to measure polyethylene wear in THA using a high resolution CT scanner: method and analysis.

Authors:  Gerald Q Maguire; Marilyn E Noz; Henrik Olivecrona; Michael P Zeleznik; Lars Weidenhielm
Journal:  ScientificWorldJournal       Date:  2014-01-22

10.  Can Na18F PET/CT be used to study bone remodeling in the tibia when patients are being treated with a Taylor Spatial Frame?

Authors:  Henrik Lundblad; Gerald Q Maguire; Henrik Olivecrona; Cathrine Jonsson; Hans Jacobsson; Marilyn E Noz; Michael P Zeleznik; Lars Weidenhielm; Anders Sundin
Journal:  ScientificWorldJournal       Date:  2014-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.