Literature DB >> 12616007

Prospective blinded evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced peripheral MR angiography, as compared with digital subtraction angiography.

Rolf Wyttenbach1, Sara Gianella, Mario Alerci, Antonio Braghetti, Luca Cozzi, Augusto Gallino.   

Abstract

PURPOSE: To compare the diagnostic accuracy of gadobenate dimeglumine (Gd-BOPTA)-enhanced versus gadoterate meglumine (Gd-DOTA)-enhanced magnetic resonance (MR) angiography in patients with peripheral arterial occlusive disease (PAOD).
MATERIALS AND METHODS: Fifty-six patients underwent MR angiography enhanced with either Gd-DOTA (28 patients) or Gd-BOPTA (28 patients). All arterial segments from the renal arteries to the distal run-off vessels were evaluated for disease severity. The sensitivity, specificity, and accuracy of MR angiography enhanced with both agents separately were evaluated with a paired t test; digital subtraction angiography was the reference standard. Interobserver variability was assessed by using the Cohen test.
RESULTS: Diagnostic MR angiograms were obtained in all 56 patients. Overall, sensitivity and specificity of Gd-DOTA-enhanced MR angiography were 96% and 93%, respectively, for observer 1 and 96% and 85%, respectively, for observer 2 (kappa = 0.82). Corresponding values for Gd-BOPTA-enhanced MR angiography were 94% and 93%, respectively, for observer 1 and 94% and 89%, respectively, for observer 2 (kappa = 0.78). No consistent differences between the two contrast materials in assessment of PAOD in the renal to popliteal arteries were observed. For assessment below the knee, specificity was slightly higher in the Gd-BOPTA group-91% and 84% for observers 1 and 2, respectively-than in the Gd-DOTA group-89% and 77%, respectively (P <.01). The number of nonassessable below-the-knee segments was significantly lower in the Gd-BOPTA group: nine of 299 segments versus 25 of 312 segments in the Gd-DOTA group (P <.01).
CONCLUSION: At MR angiography of the distal run-off vessels, Gd-BOPTA yielded higher specificity and a significantly smaller number of nonassessable segments than Gd-DOTA. The diagnostic accuracy of the two gadolinium chelates at peripheral MR angiography was comparable in the renal to popliteal arteries.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12616007     DOI: 10.1148/radiol.2271011989

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  11 in total

Review 1.  [CTA and MRA in peripheral arterial disease--is DSA out?].

Authors:  T Leibecke; C Kagel; A Lubienski; S O Peters; T Jungbluth; T Helmberger
Journal:  Radiologe       Date:  2006-11       Impact factor: 0.635

Review 2.  Enabling individualized therapy through nanotechnology.

Authors:  Jason H Sakamoto; Anne L van de Ven; Biana Godin; Elvin Blanco; Rita E Serda; Alessandro Grattoni; Arturas Ziemys; Ali Bouamrani; Tony Hu; Shivakumar I Ranganathan; Enrica De Rosa; Jonathan O Martinez; Christine A Smid; Rachel M Buchanan; Sei-Young Lee; Srimeenakshi Srinivasan; Matthew Landry; Anne Meyn; Ennio Tasciotti; Xuewu Liu; Paolo Decuzzi; Mauro Ferrari
Journal:  Pharmacol Res       Date:  2010-01-05       Impact factor: 7.658

Review 3.  Diagnostic performance of computed tomography angiography and contrast-enhanced magnetic resonance angiography in patients with critical limb ischaemia and intermittent claudication: systematic review and meta-analysis.

Authors:  Sjoerd Jens; Mark J W Koelemay; Jim A Reekers; Shandra Bipat
Journal:  Eur Radiol       Date:  2013-06-26       Impact factor: 5.315

Review 4.  High-relaxivity contrast-enhanced magnetic resonance neuroimaging: a review.

Authors:  Frederik L Giesel; Amit Mehndiratta; Marco Essig
Journal:  Eur Radiol       Date:  2010-06-23       Impact factor: 5.315

5.  Comparison of gadobenate dimeglumine and gadodiamide in the evaluation of spinal vascular anatomy with MR angiography.

Authors:  M V Spampinato; S A Nguyen; Z Rumboldt
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-06       Impact factor: 3.825

6.  Quantification of global myocardial oxygenation in humans: initial experience.

Authors:  Kyle S McCommis; Robert O'Connor; Donna Lesniak; Matt Lyons; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  J Cardiovasc Magn Reson       Date:  2010-06-02       Impact factor: 5.364

7.  Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms.

Authors:  Mario Alerci; Michel Oberson; Antonella Fogliata; Augusto Gallino; Peter Vock; Rolf Wyttenbach
Journal:  Eur Radiol       Date:  2008-12-23       Impact factor: 5.315

8.  Total-body contrast-enhanced MRA on a short, wide-bore 1.5-T system: intra-individual comparison of Gd-BOPTA and Gd-DOTA.

Authors:  M Rasmus; J Bremerich; T Egelhof; R W Huegli; G Bongartz; D Bilecen
Journal:  Eur Radiol       Date:  2008-04-23       Impact factor: 5.315

Review 9.  MR angiography with blood pool contrast agents.

Authors:  Jens Bremerich; Deniz Bilecen; Peter Reimer
Journal:  Eur Radiol       Date:  2007-07-17       Impact factor: 5.315

Review 10.  Gadobenate dimeglumine (MultiHance) for magnetic resonance angiography: review of the literature.

Authors:  M Goyen; J F Debatin
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.