Literature DB >> 12615474

In situ imaging and impedance measurements of titanium surfaces using AFM and SPIS.

Jane P Bearinger1, Christine A Orme, Jeremy L Gilbert.   

Abstract

Surfaces of commercially pure titanium and titanium, 6-aluminum, 4-vanadium were subjected to simultaneous polarization/impedance testing and in situ electrochemical atomic force microscopy imaging to evaluate how the structure and properties of the passive oxide film is affected by varying potential and hydration. Current transients were acquired via a step polarization impedance spectroscopy technique: the voltage was stepped between -1 and 1 V in 50 mV increments, while current transients and surface morphology were digitally recorded. Numerical Laplace transformation applied to the current transient data provided frequency-dependent admittance (impedance(-1)). Simultaneous AFM imaging of dry surfaces, initially hydrated surfaces, and surfaces immersed and changing with potential revealed that all sample surfaces were covered with protective titanium oxide domes that grew in area and coalesced due to hydration and as a function of increasing applied voltage and time. Reversal of dome growth did not occur upon voltage reduction, while impedance behavior was quasi-reversible, suggesting independence between structural and electrical properties. Oxide growth appeared to occur in part by lateral spreading and overgrowth of domes at the oxide-solution interface. Interfacial impedance data reflect oxide passivity and n-type semiconductor behavior. Non-linear Mott-Schottky fits specified multi-layer donor concentrations between 10(18) and 10(19)cm(-3), depending on the surface.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12615474     DOI: 10.1016/s0142-9612(02)00547-1

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  4 in total

Review 1.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

2.  Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms.

Authors:  Marco S Caicedo; Lauryn Samelko; Kyron McAllister; Joshua J Jacobs; Nadim J Hallab
Journal:  J Orthop Res       Date:  2013-06-21       Impact factor: 3.494

3.  Cathodic Voltage-controlled Electrical Stimulation Plus Prolonged Vancomycin Reduce Bacterial Burden of a Titanium Implant-associated Infection in a Rodent Model.

Authors:  Scott R Nodzo; Menachem Tobias; Richard Ahn; Lisa Hansen; Nicole R Luke-Marshall; Craig Howard; Linda Wild; Anthony A Campagnari; Mark T Ehrensberger
Journal:  Clin Orthop Relat Res       Date:  2016-07       Impact factor: 4.176

Review 4.  Application of Electrochemical Atomic Force Microscopy (EC-AFM) in the Corrosion Study of Metallic Materials.

Authors:  Hanbin Chen; Zhenbo Qin; Meifeng He; Yichun Liu; Zhong Wu
Journal:  Materials (Basel)       Date:  2020-02-03       Impact factor: 3.623

  4 in total