Literature DB >> 12612466

Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT.

D P Lum1, M N Coel.   

Abstract

The aim of this study was to compare the performance of three different software packages for the calculation of ejection fraction (EF) and end diastolic volume (EDV) from gated myocardial single photon emission computed tomography studies. Two hundred patients undergoing gated stress myocardial perfusion scans were analysed retrospectively. Patients were grouped as follows: small heart (n=31), normal perfusion scan (n=71), and scan with perfusion defects (n=98). EF and EDV were calculated for each using QGS (Cedars Sinai, Los Angeles, CA), 4D-MSPECT (University of Michigan, Ann Arbor, MI), and ECT (Emory University, Atlanta, GA). Bland-Altman plots, repeated measures ANOVA, and linear regression analysis were used to compare methods. Correlation coefficients between the methods for both EF and EDV were high, greater than 0.9. However, Bland-Altman plots revealed a large standard deviation of the difference between methods, preventing the confident estimate of the value of one method from an observation of another. Despite good correlation, the variance between methods was high. These algorithms behave differently, produce widely variable results from one another, and should not be used interchangeably. It may prove prudent for laboratories to independently validate the software algorithm that is chosen against a 'gold standard' using their own population.

Entities:  

Mesh:

Year:  2003        PMID: 12612466     DOI: 10.1097/00006231-200303000-00005

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  19 in total

1.  Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.

Authors:  Claudia S A Lipke; Harald P Kühl; Bernd Nowak; Hans-Juergen Kaiser; Patrick Reinartz; Karl-Christian Koch; Udalrich Buell; Wolfgang M Schaefer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-14       Impact factor: 9.236

2.  Noninvasive modalities for the assessment of left ventricular function: all are equal but some are more equal than others.

Authors:  Tiong Keng Lim; Roxy Senior
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

3.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

4.  Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy.

Authors:  Feng Wang; Jian Zhang; Wei Fang; Shi-Hua Zhao; Min-Jie Lu; Zuo-Xiang He
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-04-18       Impact factor: 9.236

5.  Comparison of three commercially available softwares for measuring left ventricular perfusion and function by gated SPECT myocardial perfusion imaging.

Authors:  Sameer Ather; Fahad Iqbal; John Gulotta; Wael Aljaroudi; Jaekyeong Heo; Ami E Iskandrian; Fadi G Hage
Journal:  J Nucl Cardiol       Date:  2014-04-09       Impact factor: 5.952

6.  Development of a new Python-based cardiac phantom for myocardial SPECT imaging.

Authors:  Osama S Hanafy; Magdy M Khalil; Ibrahim M Khater; Haitham S Mohammed
Journal:  Ann Nucl Med       Date:  2020-10-17       Impact factor: 2.668

7.  Evaluation of the Quantitative Gated SPECT (QGS) software program in the presence of large perfusion defects.

Authors:  Yves G C J America; Jeroen J Bax; Petra Dibbets-Schneider; Ernest K J Pauwels; Ernst E Van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2005-10       Impact factor: 2.357

8.  The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies.

Authors:  Berlinda J van der Veen; Arthur J Scholte; Petra Dibbets-Schneider; Marcel P M Stokkel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-05-26       Impact factor: 9.236

9.  Automated quality control for segmentation of myocardial perfusion SPECT.

Authors:  Yuan Xu; Paul Kavanagh; Mathews Fish; James Gerlach; Amit Ramesh; Mark Lemley; Sean Hayes; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Med       Date:  2009-08-18       Impact factor: 10.057

10.  Left ventricular aneurysm in the scope of gated perfusion SPECT: accuracy of detection and ejection fraction calculation.

Authors:  Fevziye Canbaz; Tarik Basoglu; Kenan Durna; Sibel Ucak Semirgin; Sevgi Canbaz
Journal:  Int J Cardiovasc Imaging       Date:  2008-02-16       Impact factor: 2.357

View more