Literature DB >> 12601191

Acute cerebral infarction: effect of JPEG compression on detection at CT.

Yoshimitsu Ohgiya1, Takehiko Gokan, Hiroshi Nobusawa, Masanori Hirose, Noritaka Seino, Hidefumi Fujisawa, Maiko Baba, Kyoko Nagai, Keisuke Tanno, Nobuyuki Takeyama, Hirotsugu Munechika.   

Abstract

PURPOSE: To evaluate the effect of Joint Photographic Experts Group (JPEG) compression ratios of 10:1 and 20:1 on detection of acute cerebral infarction at computed tomography (CT).
MATERIALS AND METHODS: CT images obtained in 25 patients with acute cerebral infarction and 25 patients with no lesions were compressed by means of a JPEG algorithm at ratios of 10:1 and 20:1. Normal and abnormal sections (on original and compressed images) were reviewed by using a color soft-copy computed monochrome cathode ray tube monitor. Five observers rated the presence or absence of a lesion with a 50-point scale (0, definitely absent; 25, equivocal; and 50, definitely present). Diagnostic accuracy was evaluated with receiver operating characteristic (ROC) curve analysis. Significant difference was defined as a P value less than.05 for the area tested with a two-tailed paired Student t test.
RESULTS: At ROC analysis, no statistically significant difference was detected for all cases considered together (Az [area under the ROC curve] = 0.887 +/- 0.038 [mean +/- SD] on noncompressed images, Az = 0.897 +/- 0.038 on 10:1 compressed images, and Az = 0.842 +/- 0.073 on 20:1 compressed images; P >.05).
CONCLUSION: JPEG compression at ratios of 10:1 and 20:1 was tolerated in the detection of acute cerebral infarction at CT.

Entities:  

Mesh:

Year:  2003        PMID: 12601191     DOI: 10.1148/radiol.2271020067

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  JPEG2000 for automated quantification of immunohistochemically stained cell nuclei: a comparative study with standard JPEG format.

Authors:  Marylène Lejeune; Carlos López; Ramón Bosch; Anna Korzyńska; Maria-Teresa Salvadó; Marcial García-Rojo; Urszula Neuman; Łukasz Witkowski; Jordi Baucells; Joaquín Jaén
Journal:  Virchows Arch       Date:  2010-11-18       Impact factor: 4.064

2.  Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Authors:  Kyoung Ho Lee; Young Hoon Kim; Bo Hyoung Kim; Kil Joong Kim; Tae Jung Kim; Hyuk Jung Kim; Seokyung Hahn
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

3.  Roundness variation in JPEG images affects the automated process of nuclear immunohistochemical quantification: correction with a linear regression model.

Authors:  Carlos López; Joaquín Jaén Martinez; Marylène Lejeune; Patricia Escrivà; Maria T Salvadó; Lluis E Pons; Tomás Alvaro; Jordi Baucells; Marcial García-Rojo; Xavier Cugat; Ramón Bosch
Journal:  Histochem Cell Biol       Date:  2009-08-04       Impact factor: 4.304

4.  Effects of image compression on automatic count of immunohistochemically stained nuclei in digital images.

Authors:  Carlos López; Marylène Lejeune; Patricia Escrivà; Ramón Bosch; Maria Teresa Salvadó; Lluis E Pons; Jordi Baucells; Xavier Cugat; Tomás Alvaro; Joaquín Jaén
Journal:  J Am Med Inform Assoc       Date:  2008-08-28       Impact factor: 4.497

5.  User interface of a teleradiology system for the MR assessment of multiple sclerosis.

Authors:  G Luccichenti; F Cademartiri; A Pichiecchio; E Bontempi; U Sabatini; S Bastianello
Journal:  J Digit Imaging       Date:  2009-07-15       Impact factor: 4.056

6.  Development of an algorithm to automatically compress a CT image to visually lossless threshold.

Authors:  Chang-Mo Nam; Kyong Joon Lee; Yousun Ko; Kil Joong Kim; Bohyoung Kim; Kyoung Ho Lee
Journal:  BMC Med Imaging       Date:  2018-12-17       Impact factor: 1.930

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.