Literature DB >> 12591647

Simultaneous dual vessel cerebral angiography in gamma knife planning.

Seth S Joseffer1, Paul P Huang, P Kim Nelson.   

Abstract

Gamma knife radiosurgery is an effective technique for treating arteriovenous malformations. However, treatment failures can occur as a result of incomplete visualization of the arteriovenous malformation nidus. We describe the use of bilateral femoral artery catheterization and simultaneous dual vessel cerebral angiography to facilitate treatment planning during gamma knife treatment.

Entities:  

Mesh:

Year:  2003        PMID: 12591647      PMCID: PMC7974138     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  8 in total

1.  Analysis of the causes of treatment failure in gamma knife radiosurgery for intracranial arteriovenous malformations.

Authors:  Y Kwon; S R Jeon; J H Kim; J K Lee; D S Ra; D J Lee; B D Kwun
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

2.  Factors related to complete occlusion of arteriovenous malformations after gamma knife radiosurgery.

Authors:  J H Chang; J W Chang; Y G Park; S S Chung
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

3.  Analysis of treatment failure after radiosurgery for arteriovenous malformations.

Authors:  T L Ellis; W A Friedman; F J Bova; P S Kubilis; J M Buatti
Journal:  J Neurosurg       Date:  1998-07       Impact factor: 5.115

4.  Reproducibility analysis of a new objective method for measuring arteriovenous malformation nidus size at angiography.

Authors:  Steven G Imbesi; Kimberly Knox; Charles W Kerber
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

5.  Combining stereotactic angiography and 3D time-of-flight magnetic resonance angiography in treatment planning for arteriovenous malformation radiosurgery.

Authors:  G Bednarz; B Downes; M Werner-Wasik; R H Rosenwasser
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

6.  Interim report on the radiosurgical treatment of cerebral arteriovenous malformations. The influence of size, dose, time, and technical factors on obliteration rate.

Authors:  Y Yamamoto; R J Coffey; D A Nichols; E G Shaw
Journal:  J Neurosurg       Date:  1995-11       Impact factor: 5.115

7.  Stereotactic magnetic resonance angiography for targeting in arteriovenous malformation radiosurgery.

Authors:  D Kondziolka; L D Lunsford; E Kanal; L Talagala
Journal:  Neurosurgery       Date:  1994-10       Impact factor: 4.654

8.  Factors associated with successful arteriovenous malformation radiosurgery.

Authors:  B E Pollock; J C Flickinger; L D Lunsford; A Maitz; D Kondziolka
Journal:  Neurosurgery       Date:  1998-06       Impact factor: 4.654

  8 in total
  1 in total

1.  The Efficacy of Simultaneous Bilateral Internal Carotid Angiography during Coil Embolization for Anterior Communicating Artery Aneurysms.

Authors:  Soon Chan Kwon; Jun Bum Park; Shang Hun Shin; Hong Bo Sim; In Uk Lyo; Young Kim
Journal:  J Korean Neurosurg Soc       Date:  2011-05-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.