The effect of disinfectant agents in eliminating the contamination of dental unit water.

M Ozcan1, Y Kulak, E Kazazoglu.   

Abstract

High concentrations of water-borne organisms cause multiple public health problems. Contamination of water exiting the dental unit water lines could be inhibited with the use of some disinfectants. The purpose of this investigation was to establish the effect of two disinfectants and to test their capacity to eliminate colony forming units (CFU) per mL. Vacuum lines of four chairs were treated for a total of 2 weeks. Two disinfectants (Bio 2000 and Alpron) were used as per manufacturer's instructions. Water samples for hetereothrophic counts from each unit's air/water syringe line were collected before treating the first patient of the day. Baseline, daily, first and second week samples of 10 mL were plated on blood agar plates and eosin ethylene blue agar. For meosifilic bacterial counts, Mueller Hinton agar plates with 1 mL direct and 1/10 were used in sterile serum and CFU were counted. The suspected colonies were further evaluated using API 20E and API 20NE. No Gram(-) opportunistic pathogens were found during the entire observation. Baseline contamination level (>102 CFU mL-1) without use of disinfectants was significantly higher (P < 0.0001) than at both first and second weeks when disinfectants were used. No colony was formed when Bio 2000 was used after both first and second weeks, whereas small number of CFU mL-1 was found at the end of the first week when Alpron (<10) was used. In conclusion, when used daily, both disinfectants prevent the development of bacterial contamination after first and second weeks with no significant differences (P=0.35).

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12588502     DOI: 10.1046/j.1365-2842.2003.01067.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.

Authors:  Jie Luo; Nuala Porteous; Yuyu Sun
Journal:  ACS Appl Mater Interfaces       Date:  2011-07-01       Impact factor: 9.229

2.  Breaking the Chain of Infection: Dental Unit Water Quality Control.

Authors:  Amrita Pawar; Sandeep Garg; Sonia Mehta; Rajat Dang
Journal:  J Clin Diagn Res       Date:  2016-07-01

3.  Evaluation of antimicrobial-antibiofilm activity of a hydrogen peroxide decontaminating system used in dental unit water lines.

Authors:  Germano Orrù; Susanna Del Nero; Enrica Tuveri; Maria Laura Ciusa; Francesca Pilia; Matteo Erriu; Ginevra Orrù; Manuele Liciardi; Vincenzo Piras; Gloria Denotti
Journal:  Open Dent J       Date:  2010-07-20

4.  Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European Union.

Authors:  A J Schel; P D Marsh; D J Bradshaw; M Finney; M R Fulford; E Frandsen; E Østergaard; J M ten Cate; W R Moorer; A Mavridou; J J Kamma; G Mandilara; L Stösser; S Kneist; R Araujo; N Contreras; P Goroncy-Bermes; D O'Mullane; F Burke; P O'Reilly; G Hourigan; M O'Sullivan; R Holman; J T Walker
Journal:  Appl Environ Microbiol       Date:  2006-02       Impact factor: 4.792

5.  Risk of Fungal Infection to Dental Patients.

Authors:  Jaqueline Lopes Damasceno; Rafael Aparecido Dos Santos; Amir Horiquini Barbosa; Luciana Assirati Casemiro; Regina Helena Pires; Carlos Henrique Gomes Martins
Journal:  ScientificWorldJournal       Date:  2017-06-14

6.  Disinfection of dental unit water line using aloe vera: in vitro study.

Authors:  Sonia Pareek; Anup Nagaraj; Prateek Sharma; Mansi Atri; Satinder Walia; Shravani Naidu; Asif Yousuf
Journal:  Int J Dent       Date:  2013-09-08

7.  Efficacy of BRS® and Alpron®/Bilpron® Disinfectants for Dental Unit Waterlines: A Six-Year Study.

Authors:  Alexandre Baudet; Julie Lizon; Jean-Marc Martrette; Frédéric Camelot; Arnaud Florentin; Céline Clément
Journal:  Int J Environ Res Public Health       Date:  2020-04-12       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.