Literature DB >> 12588322

Haemodynamic monitoring and liver function evaluation by pulsion cold system Z-201 (PCS) during orthotopic liver transplantation.

Susana Díaz1, José Pérez-Peña, Javier Sanz, Luis Olmedilla, Ignacio Garutti, José M Barrio.   

Abstract

Pulsion cold system (PCS, COLD) is a haemodynamic monitoring system that allows measurement of cardiac output (CO), partial blood volumes, lung water, and liver function. The aim of the study was to evaluate this monitoring system during human orthotopic liver transplantation (OLT) for the following: (a) to determine agreement between CO measurements via pulmonary artery thermodilution (CO TDpa), and aortic transpulmonary thermodilution (CO TDa); (b) to compare the preload dates obtained with the COLD with central venous pressure (CVP) and pulmonary capillary wedge (PCWP); and (c) to assess the use of the plasma disappearance rate (PDR) of indocyanine green (ICG) as a measure of graft function. Fifteen consecutive patients undergoing OLT were studied. Each patient received a pulmonary artery catheter and a 5F aortic catheter with an integrated thermistor. The thermistor of the aortic catheter were connected to one computer system (COLD-Z201, Pulsion Medical Systems, Munich, Germany). Haemodynamic data were registered an all the phases of OLT. PDR was measured during surgery in 12 patients. Correlations between PDR and the other markers of graft function (transaminases, protrombine time, and bile production) were sought. The correlation coefficient between CO TDa (COLD) and CO TDpa was r = 0.766 (p < 0.001), and an additional analysis according to Bland-Altman was also performed. There was a better correlation between the cardiac index (determined by two monitoring systems) and the volume measurements than the correlation observed with pressure preload parameters. The best correlations were found between the cardiac index in the femoral artery and intrathoracic blood volume index (ITBVI) and pulmonary blood volume index (PBVI) (r = 0.79 and r = 0.72, respectively; p < 0.01). PDR measured in the group patients with bad early graft function were lower (13.6 +/- 2.7) than those in the group with a good graft function (21.6 +/- 9) (p < 0.05). The degree of discrepancy between femoral and pulmonary thermodilution cardiac output measures is very wide during OLT so as to make the techniques using the COLD machine clinically useless. On the other hand, the volumes measured by COLD, specially ITBVI and PBVI, are more useful to asses the pre-load than pressure measurements. In OLT, the PDR measured within the first few hours after liver reperfusion may become a useful tool for early diagnosis of primary graft dysfunction (PDF).

Entities:  

Mesh:

Year:  2003        PMID: 12588322     DOI: 10.1034/j.1399-0012.2003.02072.x

Source DB:  PubMed          Journal:  Clin Transplant        ISSN: 0902-0063            Impact factor:   2.863


  5 in total

Review 1.  Perioperative monitoring in liver transplant patients.

Authors:  Shweta Singh; Vaibhav Nasa; Manish Tandon
Journal:  J Clin Exp Hepatol       Date:  2012-09-21

Review 2.  Quantitative assessment of hepatic function and its relevance to the liver surgeon.

Authors:  G Morris-Stiff; D Gomez; R Prasad
Journal:  J Gastrointest Surg       Date:  2008-07-12       Impact factor: 3.452

3.  Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation.

Authors:  Lukas Bruegger; Peter Studer; Stefan W Schmid; Gunther Pestel; Juerg Reichen; Christian Seiler; Daniel Candinas; Daniel Inderbitzin
Journal:  J Gastrointest Surg       Date:  2007-10-25       Impact factor: 3.452

4.  The combination of MELD score and ICG liver testing predicts length of stay in the ICU and hospital mortality in liver transplant recipients.

Authors:  Stephanie Klinzing; Giovanna Brandi; Paul A Stehberger; Dimitri A Raptis; Markus Béchir
Journal:  BMC Anesthesiol       Date:  2014-11-15       Impact factor: 2.217

5.  Comparison of the ability of the PDD-ICG clearance test, CTP, MELD, and MELD-Na to predict short-term and medium-term mortality in patients with decompensated hepatitis B cirrhosis.

Authors:  Xiang-Pu Cheng; Jing Zhao; Yu Chen; Fan-Kun Meng; Bin Xu; Hong-Wei Yu; Qing-Hua Meng; Yan-Min Liu; Shi-Bin Zhang; Sha Meng; Jing-Yun Zhang; Jin-Yan Zhang; Zhong-Ping Duan; Su-Jun Zheng
Journal:  Eur J Gastroenterol Hepatol       Date:  2016-04       Impact factor: 2.566

  5 in total