Literature DB >> 12583563

Influence of gravity on radiographic contrast material-based measurements of regional blood flow distribution.

Anne V Clough1, Steven T Haworth, David L Roerig, Eric A Hoffman, Christopher A Dawson.   

Abstract

RATIONALE AND
OBJECTIVES: Radiographic measurement of regional blood flow distribution in the lungs is potentially biased because the contrast material used to track flow is denser than blood. The authors performed this study to evaluate the effect of gravity on flow estimates by using an experimental test phantom and numeric simulations.
MATERIALS AND METHODS: Cross-sectionally uniform boluses of radiopaque contrast material were delivered at the upstream end of a horizontal inlet tube connected to a downstream axisymmetric bifuration attached to collecting tubing spirals. The phantom was imaged by using both planar angiography and dynamic multi-detector row computed tomography (CT) during the passage of the bolus through the phantom. The images were analyzed to determine the relative amounts of contrast material traveling through the top and bottom branches of the bifurcation by using varying Reynolds numbers and ratios of inlet tube volume to bolus volume. Numeric simulations of flow within a straight channeL with use of a dispersion operator intended to simulate settling of the bolus due to gravity, were performed under conditions representative of those in the experiments.
RESULTS: When the plane of the bifurcation was vertical and actual flow through the two branches was equal, the fraction of contrast material passing through the downward-directed branch increased with decreasing Reynolds number and increasing inlet tube-bolus volume ratio. This occurred in both the experiments and the simulations.
CONCLUSION: Because in the circulation Reynolds number decreases and pathway length increases with decreasing vessel diameter, the accuracy of regional flow measurements obtained with angiography or CT within the lungs may be limited by density differences between contrast material and blood.

Mesh:

Substances:

Year:  2003        PMID: 12583563     DOI: 10.1016/s1076-6332(03)80036-3

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

1.  Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent.

Authors:  Zhou Wang; Ciprian Ionita; Stephen Rudin; Kenneth R Hoffmann; Adam B Paxton; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-04

2.  The mixability of angiographic contrast with arterial blood.

Authors:  Baruch B Lieber; Chander Sadasivan; Qing Hao; Jaehoon Seong; Liliana Cesar
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Clinical feasibility of pulmonary perfusion analysis using dynamic computed tomography and a gamma residue function.

Authors:  Yasuhiko Shimatani; Kazuhiko Kodani; Junko Okada; Motoki Ametani; Toshio Kaminou; Toshihide Ogawa
Journal:  Jpn J Radiol       Date:  2013-01-12       Impact factor: 2.374

4.  Quantifying heterogeneity in emphysema from high-resolution computed tomography: a lung tissue research consortium study.

Authors:  Cuneyt Yilmaz; Dan M Dane; Nova C Patel; Connie C W Hsia
Journal:  Acad Radiol       Date:  2012-10-30       Impact factor: 3.173

5.  Value of Dual-energy Lung Perfusion Imaging Using a Dual-source CT System for the Pulmonary Embolism.

Authors:  Jinshan Zhang; Jing Cai; Shulan Liu; Xianmei Zhang
Journal:  Open Life Sci       Date:  2018-04-18       Impact factor: 0.938

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.