Literature DB >> 12579052

Comparison of 10 different hemostatic dressings in an aortic injury.

Jill L Sondeen1, Anthony E Pusateri, Valerie G Coppes, Charla E Gaddy, John B Holcomb.   

Abstract

BACKGROUND: Uncontrolled hemorrhage is the leading preventable cause of death on the battlefield. Similarly, hemorrhage accounts for 80% of all deaths within the first 48 hours of injury in civilian trauma patients. New methods of hemostasis are required to reduce hemorrhagic mortality. The purpose of this study was to compare nine hemostatic dressings for their efficacy in controlling bleeding from an otherwise fatal aortic injury in a pig model. Each hemostatic dressing was compared with the current standard U.S. Army field gauze dressing for a 1-hour period.
METHODS: Fifty-nine anesthetized pigs were instrumented with catheters and splenectomized. Nine test dressings (n = 5 per group) and two control groups (gauze, n = 9; suture, n = 5) were applied to a 4.4-mm aortotomy through the spraying jet of blood, and direct pressure was held for 4 minutes and then released. Survival, blood loss, and other variables were measured over a 1-hour period.
RESULTS: All animals with fibrin dressing and those receiving suture repair (five of five in both groups) survived the 1-hour observation period with minimal bleeding in the postocclusion period (< 37 mL). Those in the other dressing groups exsanguinated within 10 minutes, except for two animals in the gauze group surviving 1 hour.
CONCLUSION: With one 4-minute application, a single fibrin dressing stopped bleeding from an aortotomy, which was equivalent to sutured repair. No other test group exhibited any evidence of significant hemostatic efficacy.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12579052     DOI: 10.1097/01.TA.0000037431.19185.B4

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  10 in total

Review 1.  Combat casualty care research: from bench to the battlefield.

Authors:  Hasan B Alam; Elena Koustova; Peter Rhee
Journal:  World J Surg       Date:  2005       Impact factor: 3.352

Review 2.  Topical and effective hemostatic medicines in the battlefield.

Authors:  Yin-Juan Zhang; Bo Gao; Xi-Wen Liu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 3.  Use of local pro-coagulant haemostatic agents for intra-cavity control of haemorrhage after trauma.

Authors:  A Navarro; A Brooks
Journal:  Eur J Trauma Emerg Surg       Date:  2014-08-26       Impact factor: 3.693

Review 4.  Current use of live tissue training in trauma: a descriptive systematic review.

Authors:  Luis Teodoro da Luz; Bartolomeu Nascimento; Homer Tien; Michael J Kim; Avery B Nathens; Savvas Vlachos; Elon Glassberg
Journal:  Can J Surg       Date:  2015-06       Impact factor: 2.089

5.  Hemostatic gauze based on chitosan and hydroquinone: preparation, characterization and blood coagulation evaluation.

Authors:  Roberta Cassano; Maria Luisa Di Gioia; Silvia Mellace; Nevio Picci; Sonia Trombino
Journal:  J Mater Sci Mater Med       Date:  2017-11-07       Impact factor: 3.896

6.  Celox-coated gauze for the treatment of civilian penetrating trauma: a randomized clinical trial.

Authors:  Hamid Reza Hatamabadi; Fatemeh Asayesh Zarchi; Hamid Kariman; Ali Arhami Dolatabadi; Ali Tabatabaey; Afshin Amini
Journal:  Trauma Mon       Date:  2015-01-20

7.  Effects of folk medicinal plant extract Ankaferd Blood Stopper on early bone healing.

Authors:  Sabri Cemil Işler; Sabit Demircan; Sirmahan Cakarer; Zerrin Cebi; Cengizhan Keskin; Merva Soluk; Emir Yüzbaşioğlu
Journal:  J Appl Oral Sci       Date:  2010 Jul-Aug       Impact factor: 2.698

Review 8.  Methods for improved hemorrhage control.

Authors:  John B Holcomb
Journal:  Crit Care       Date:  2004-06-14       Impact factor: 9.097

9.  Severe traumatic injury during long duration spaceflight: Light years beyond ATLS.

Authors:  Andrew W Kirkpatrick; Chad G Ball; Mark Campbell; David R Williams; Scott E Parazynski; Kenneth L Mattox; Timothy J Broderick
Journal:  J Trauma Manag Outcomes       Date:  2009-03-25

10.  Electric- Field-Modified In Situ Precise Deposition of Electrospun Medical Glue Fibers on the Liver for Rapid Hemostasis.

Authors:  Wei-Ling Luo; Jun Zhang; Xuan Qiu; Li-Juan Chen; Jie Fu; Peng-Yue Hu; Xin Li; Ren-Jie Hu; Yun-Ze Long
Journal:  Nanoscale Res Lett       Date:  2018-09-10       Impact factor: 4.703

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.