Hemodilution does not alter the aortic-to-femoral arterial pressure difference in dogs.

J Urzua1, G Nunez, G Lema, R Canessa, C Sacco.   

Abstract

INTRODUCTION: Distal arterial pressure normally differs from aortic pressure. This difference is modified by changes of vascular resistance. Hemodilution, due to decreased viscosity, decreases vascular resistance. Therefore, the difference between aortic and distal arterial pressures could be altered as well. We investigated whether acute hemodilution affected this difference in dogs.
METHODS: Eleven mongrel dogs weighing 16.6 +/- 4.4 kg were anesthetized with pentobarbital and sufentanyl and mechanically ventilated. Arterial presssure was recorded using Millar catheter-tipped pressure transducers in the proximal aorta and in the distal femoral artery. An electromagnetic flowmeter probe was placed around the aorta. Effective downstream pressure was estimated by extrapolation of exponential arterial pressure decay during 3-second occlusion of the proximal aorta. Hemodilution was effected by removal of 30 ml/kg of blood and replacement with 60 ml/kg of warmed saline. In addition, the effects of 1 microg/kg phenylephrine and 4 microg/kg of sodium nitroprusside were measured before and after hemodilution.
RESULTS: Hemodilution decreased hematocrit from 39 +/- 11.2% to 25.6 +/- 4.95%. Systolic and mean pressures were unchanged but aortic diastolic pressure decreased significantly, from 86 +/- 17 to 79 +/- 15 mmHg (p < 0.005). Peak systolic pressure was 13.5 +/- 7.2 mmHg higher in the femoral artery than in the aorta before, and 16 +/- 8.7 mmHg after, hemodilution (p > 0.05). Nitroprusside decreased the femoral to aortic peak systolic pressure difference from 14.3 +/- 6.3 to 7.7 +/- 15.3 mmHg, p = 0.05 before hemodilution and from 14.3 +/- 8.8 to 2.5 +/- 11 mmHg, p < 0.005 afterwards. Hemodilution significantly decreased the effective downstream pressure, from 44 +/- 9 to 36 +/- 6.8 mmHg in the aorta (p < 0.05), and from 51 +/- 2 to 37 +/- 3.1 mmHg in the distal femoral artery (p < 0.05).
CONCLUSION: Acute hemodilution did not alter the aortic-to-distal arterial pressure difference in dogs.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 12578039     DOI: 10.1023/a:1009986327155

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  15 in total

1.  HEMODYNAMICS OF COLLAPSIBLE VESSELS WITH TONE: THE VASCULAR WATERFALL.

Authors:  S PERMUTT; R L RILEY
Journal:  J Appl Physiol       Date:  1963-09       Impact factor: 3.531

2.  Effect of perfusate rheology on the diastolic coronary pressure-flow relationship.

Authors:  M Drossner; T Aversano
Journal:  Am J Physiol       Date:  1990-08

Review 3.  Cardiac mechanical energy and effects on the arterial tree.

Authors:  H R Muñoz; C M Sacco
Journal:  J Cardiothorac Vasc Anesth       Date:  1997-05       Impact factor: 2.628

4.  Starling resistor versus compliance. Which explains the zero-flow pressure of a dynamic arterial pressure-flow relation?

Authors:  S Magder
Journal:  Circ Res       Date:  1990-07       Impact factor: 17.367

5.  Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man.

Authors:  L B Rowell; G L Brengelmann; J R Blackmon; R A Bruce; J A Murray
Journal:  Circulation       Date:  1968-06       Impact factor: 29.690

6.  Enhanced cardiac performance following cardiopulmonary bypass.

Authors:  J Urzua; A M Zurick; N J Starr; D M Cosgrove; J P Yared; F G Estafanous
Journal:  J Cardiovasc Surg (Torino)       Date:  1985 Jan-Feb       Impact factor: 1.888

7.  Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressures.

Authors:  J Urzua; D I Sessler; G Meneses; C M Sacco; R Canessa; G Lema
Journal:  J Clin Monit       Date:  1994-07

8.  Mechanism of systemic vasodilation during normovolemic hemodilution.

Authors:  D N Doss; F G Estafanous; C M Ferrario; J M Brum; P A Murray
Journal:  Anesth Analg       Date:  1995-07       Impact factor: 5.108

9.  Reliability of the radial arterial pressure during anesthesia. Is wrist compression a possible diagnostic test?

Authors:  A L Pauca; S L Wallenhaupt; N D Kon
Journal:  Chest       Date:  1994-01       Impact factor: 9.410

10.  A comparison of brachial, femoral, and aortic intra-arterial pressures before and after cardiopulmonary bypass.

Authors:  G P Gravlee; S D Brauer; M F O'Rourke; A P Avolio
Journal:  Anaesth Intensive Care       Date:  1989-08       Impact factor: 1.669

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.