Literature DB >> 12577297

In vivo monitoring of rat brain metabolites during vigabatrin treatment using localized 2D-COSY.

John W R Welch1, Kishore Bhakoo, Ruth M Dixon, Peter Styles, Nicola R Sibson, Andrew M Blamire.   

Abstract

A two-dimensional COSY-based localization sequence was designed to allow the in vivo monitoring of proton metabolites in rat brain [particularly gamma-aminobutyric acid (GABA), glutamine, taurine and myo-inositol]. The sequence incorporated OSIRIS signal localization, B1-insensitive water suppression and phase-sensitive COSY acquisition. The method was used to study the effects of the GABA-transaminase inhibitor vigabatrin on rat brain metabolite concentrations. Wistar rats were treated daily for 3 days with an oral dose of vigabatrin (200 mg/kg, n = 4). Localized COSY spectra were obtained during a 120 min acquisition from a 270 microl central brain voxel and compared with nine untreated control animals. Significant elevations were observed in GABA (267% of control, p < 0.005, Mann-Witney test), glutamine (130% of control, p < 0.005) and taurine (113% of control, p < 0.05). Changes in GABA and taurine were consistent with previous data on the action of Vigabatrin, and support a previously hypothesized link between these compounds. The increase in glutamine was more surprising and may reflect the balance between the level and/or site of GABA-transaminase inhibition and downregulation of GABA synthesis. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12577297     DOI: 10.1002/nbm.809

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Two-dimensional MR spectroscopy of healthy and cancerous prostates in vivo.

Authors:  M Albert Thomas; Thomas Lange; S Sendhil Velan; Rajakumar Nagarajan; Steve Raman; Ana Gomez; Daniel Margolis; Stephany Swart; Raymond R Raylman; Rolf F Schulte; Peter Boesiger
Journal:  MAGMA       Date:  2008-07-17       Impact factor: 2.310

2.  Retrospective correction of frequency drift in spectral editing: The GABA editing example.

Authors:  Jan Willem van der Veen; Stefano Marenco; Karen F Berman; Jun Shen
Journal:  NMR Biomed       Date:  2017-04-03       Impact factor: 4.044

Review 3.  In vivo 2D magnetic resonance spectroscopy of small animals.

Authors:  P Méric; G Autret; B T Doan; B Gillet; C Sébrié; J-C Beloeil
Journal:  MAGMA       Date:  2004-12-29       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.