Literature DB >> 12572746

Impedance cardiographic measurement of the physiological response to the Valsalva manoeuvre.

R P Patterson1, J Zhang.   

Abstract

The Valsalva manoeuvre was performed, with airway pressures of 10, 20, 30, 40 and 50 mmHg, on 11 healthy male subjects in both the standing and supine positions, and was evaluated with impedance cardiography using the Minnesota impedance cardiograph. Along with the impedance waveform, the output of a finger photoplethysmograph was recorded. The ratios of the amplitude of the finger and impedance pulses at the end of a 10s strain phase during the Valsalva manoeuvre were compared with those of the control period. The results in the standing position showed the impedance ratio changed from 0.81 to 0.61 as the airway pressure increased from 10 to 50 mmHg, whereas, over the same pressure range, the finger pulse ratio changed from 0.44 to 0.21. In the supine position, the response was similar to that for standing for most pressures. Upon release of the pressure, the impedance showed an immediate, large decrease, which suggests a significant right-heart and vena cava component in the impedance cardiographic signal. The results show that the impedance signals responded similarly to those of previous studies of central arterial pressure during the Valsalva manoeuvre, whereas the finger pulse decrease was approximately twice as much.

Mesh:

Year:  2003        PMID: 12572746     DOI: 10.1007/BF02343537

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  A new method of predicting pulmonary capillary wedge pressure: the arterial pressure ratio.

Authors:  H Uehara; I Takenaka; K Aoyama; T Kadoya; T Sata; A Shigematsu
Journal:  Anaesthesia       Date:  2000-02       Impact factor: 6.955

2.  A noninvasive method of predicting pulmonary-capillary wedge pressure.

Authors:  K M McIntyre; J A Vita; C T Lambrew; J Freeman; J Loscalzo
Journal:  N Engl J Med       Date:  1992-12-10       Impact factor: 91.245

3.  The Valsalva maneuver as a test of cardiac function; pathologic physiology and clinical significance.

Authors:  R GORLIN; J H KNOWLES; C F STOREY
Journal:  Am J Med       Date:  1957-02       Impact factor: 4.965

4.  The peripheral circulation in circulatory failure.

Authors:  E P SHARPEY-SCHAFER
Journal:  Br Med Bull       Date:  1952       Impact factor: 4.291

5.  Development and evaluation of an impedance cardiac output system.

Authors:  W G Kubicek; J N Karnegis; R P Patterson; D A Witsoe; R H Mattson
Journal:  Aerosp Med       Date:  1966-12

6.  Left ventricular dysfunction--bedside Valsalva manoeuvre.

Authors:  M J Zema; B Restivo; T Sos; K W Sniderman; S Kline
Journal:  Br Heart J       Date:  1980-11
  6 in total
  2 in total

1.  Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

Authors:  Harry A Silber; Jeffrey C Trost; Peter V Johnston; W Lowell Maughan; Nae-Yuh Wang; Edward K Kasper; Thomas R Aversano; David E Bush
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-03-02       Impact factor: 4.733

2.  Splanchnic hyperemia and hypervolemia during Valsalva maneuver in postural tachycardia syndrome.

Authors:  Julian M Stewart; Marvin S Medow; Leslie D Montgomery; June L Glover; Mark M Millonas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-06-17       Impact factor: 4.733

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.