Literature DB >> 12571846

Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: comparison of standing anteroposterior and Lyon schuss views.

Eric Vignon1, Muriel Piperno, Marie-Pierre Hellio Le Graverand, Steven A Mazzuca, Kenneth D Brandt, Pierre Mathieu, Huguett Favret, Martine Vignon, Florence Merle-Vincent, Thierry Conrozier.   

Abstract

OBJECTIVE: To evaluate progression of joint space narrowing in radiographs of osteoarthritic (OA) knees imaged in both the standing anteroposterior (AP) and the Lyon schuss positions, using alternative methods to measure joint space width (JSW).
METHODS: Standing AP (extended view) and Lyon schuss (posteroanterior [PA] view, with 20-30 degrees of flexion) radiographic images of 58 OA knees were obtained twice (at baseline and 2 years later). With both methods, fluoroscopy was used to align the anterior and posterior margins of the medial or lateral tibial plateau with the central x-ray beam. Minimum JSW, mean JSW, and joint space area (JSA) of the medial or lateral femorotibial joint space were measured using a new digital image analysis system. The effects of knee flexion versus extension and parallel versus nonparallel tibial plateau alignment were evaluated with respect to the reproducibility of JSW in repeated examinations (intraclass correlation coefficient [ICC]), the mean of within-knee standard deviations of repeated measurements (SD(m)), and the sensitivity to changes in JSW in serial radiographs (standardized response mean [SRM]).
RESULTS: The performance of the new software, as assessed by the reproducibility of repeated measurements of minimum JSW on the same image, was excellent in both the standing AP (ICC = 0.98) and Lyon schuss radiographs (2 SD(m) = 0.5 mm, ICC = 0.98). The reproducibility in different radiographs of the same knee was not evaluated. However, over 2 years, the mean (+/- SD) decrease in the minimum JSW of OA knees was 0.17 +/- 0.75 mm in standing AP radiographs (P not significant) and 0.24 +/- 0.50 mm in Lyon schuss views (P = 0.007), with SRMs of 0.23 and 0.48, respectively. The quality of alignment of the tibial plateau was satisfactory (<1 mm between anterior and posterior margins of the medial tibial plateau) in 66% of the pairs of Lyon schuss radiographs and in 57% of the pairs of standing AP radiographs. In the Lyon schuss radiographs, SRM was highly dependent on tibial plateau alignment. Minimum JSW was more sensitive to change than was mean JSW or JSA, in paired Lyon schuss radiographs that exhibited satisfactory alignment.
CONCLUSION: Compared with the standing AP radiograph, PA imaging of the knee in 20-30 degrees flexion (the schuss position) increases the reproducibility of radiographic JSW measurements in OA knees and the sensitivity to change in JSW in serial radiographs. Sensitivity to change in minimum JSW is notably increased by aligning the medial tibial plateau with the central x-ray beam in the Lyon schuss radiograph.

Entities:  

Mesh:

Year:  2003        PMID: 12571846     DOI: 10.1002/art.10773

Source DB:  PubMed          Journal:  Arthritis Rheum        ISSN: 0004-3591


  56 in total

1.  Effects of glucosamine and chondroitin supplementation on knee osteoarthritis: an analysis with marginal structural models.

Authors:  Shibing Yang; Charles B Eaton; Timothy E McAlindon; Kate L Lapane
Journal:  Arthritis Rheumatol       Date:  2015-03       Impact factor: 10.995

2.  Stress radiography for osteoarthritis of the knee: a new technique.

Authors:  Karl Eriksson; O Sadr-Azodi; C Singh; L Osti; J Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-08       Impact factor: 4.342

3.  Chondrocalcinosis, osteophytes and osteoarthritis.

Authors:  K D Brandt
Journal:  Ann Rheum Dis       Date:  2003-06       Impact factor: 19.103

4.  Cross-sectional comparison of extended anteroposterior and posteroanterior fixed flexion positioning to assess radiographic osteoarthritis at the knee: the Johnston County Osteoarthritis Project.

Authors:  Amanda E Nelson; Jordan B Renner; Xiaoyan A Shi; Jack H Shreffler; Todd A Schwartz; Joanne M Jordan
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-09       Impact factor: 4.794

5.  Magnitude and regional distribution of cartilage loss associated with grades of joint space narrowing in radiographic osteoarthritis--data from the Osteoarthritis Initiative (OAI).

Authors:  F Eckstein; W Wirth; D J Hunter; A Guermazi; C K Kwoh; D R Nelson; O Benichou
Journal:  Osteoarthritis Cartilage       Date:  2010-02-18       Impact factor: 6.576

6.  Comparison of quantitative and semiquantitative indicators of joint space narrowing in subjects with knee osteoarthritis.

Authors:  S A Mazzuca; K D Brandt; B P Katz; K A Lane; K A Buckwalter
Journal:  Ann Rheum Dis       Date:  2005-05-26       Impact factor: 19.103

7.  Evidence-based practice in the utilization of knee radiographs--a survey of all members of the British Orthopaedic Association.

Authors:  S Bhatnagar; R Carey-Smith; C Darrah; P Bhatnagar; M M Glasgow
Journal:  Int Orthop       Date:  2006-04-27       Impact factor: 3.075

8.  Superiority of the Lyon schuss view over the standing anteroposterior view for detecting joint space narrowing, especially in the lateral tibiofemoral compartment, in early knee osteoarthritis.

Authors:  F Merle-Vincent; E Vignon; K Brandt; M Piperno; F Coury-Lucas; T Conrozier; P Mathieu; M P Hellio Le Graverand
Journal:  Ann Rheum Dis       Date:  2007-01-16       Impact factor: 19.103

9.  Image interpolation improves the zonal analysis of cartilage T2 relaxation in MRI.

Authors:  Farid Badar; Yang Xia
Journal:  Quant Imaging Med Surg       Date:  2017-04

10.  Location specific radiographic joint space width for osteoarthritis progression.

Authors:  G Neumann; D Hunter; M Nevitt; L B Chibnik; K Kwoh; H Chen; T Harris; S Satterfield; J Duryea
Journal:  Osteoarthritis Cartilage       Date:  2008-11-12       Impact factor: 6.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.