Literature DB >> 12571501

Comparison of the mechanical properties of different tension band materials and suture techniques.

R M Harrell1, J Tong, P S Weinhold, Laurence E Dahners.   

Abstract

OBJECTIVES: This study determined the tensile properties of 18-gauge stainless steel wire, 5-mm woven polyester (Mersilene) tape, and multiple loop configurations of No. 5 braided polyester suture (Ethibond).
DESIGN: Mechanical property testing. INTERVENTION: Single loops of stainless steel wire, Mersilene, and Ethibond were tested to determine their mechanical properties. Ethibond was tested with different numbers of loops and different knot configurations. MAIN OUTCOME MEASURES: Stiffness, load at failure, and elongation at failure.
RESULTS: One loop of Mersilene and two loops of Ethibond had similar loads at failure, but the load at failure was significantly higher for stainless steel wire. Four loops of Ethibond withstood a similar failure load to stainless steel wire, but the failure load of the Ethibond suture was greater than the yield load of stainless steel wire. Stainless steel wire had a higher stiffness than both Ethibond and Mersilene. No difference was found in the failure load between different Ethibond knot configurations. The individually tied suture configuration resulted in a higher stiffness than the single-knot configuration. The elongation at failure was not statistically different among the different knot configurations and materials, with the exception of Mersilene tape. Mersilene tape demonstrated a significant increase in elongation at failure as compared to the other materials and knot configurations.
CONCLUSION: It appears that multiple loops of Ethibond can substitute for stainless steel wire in situations where a compliant repair is suitable (support of a patellar tendon repair), but may not be satisfactory for rigid fixation (tension band fixation of a fracture). There appears to be no significant difference in strength but a small decrease in stiffness between tying multiple suture loops in one knot as opposed to individual knots.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12571501     DOI: 10.1097/00005131-200302000-00007

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  7 in total

1.  Material properties of common suture materials in orthopaedic surgery.

Authors:  S Najibi; R Banglmeier; Jm Matta; M Tannast
Journal:  Iowa Orthop J       Date:  2010

Review 2.  Extensor mechanism ruptures.

Authors:  Reha N Tandogan; Esref Terzi; Enrique Gomez-Barrena; Bruno Violante; Asim Kayaalp
Journal:  EFORT Open Rev       Date:  2022-05-31

Review 3.  Achilles tendon rupture: avoiding tendon lengthening during surgical repair and rehabilitation.

Authors:  Javier Maquirriain
Journal:  Yale J Biol Med       Date:  2011-09

4.  Can tape-screw fixation of a quadrupled semitendinosus graft in a full-length tibial tunnel provide superior fixation compared with a doubled semitendinosus-gracilis held with an interference screw? A matched-pair cadaveric biomechanical comparison.

Authors:  Christopher J Vertullo; Joseph Cadman; Dané Dabirrahmani; Richard Appleyard
Journal:  J Orthop Traumatol       Date:  2018-08-21

5.  Biomechanical Properties and Biocompatibility of a Non-Absorbable Elastic Thread.

Authors:  Yeji Choi; Moonseok Kang; Moon Seop Choi; Jennifer Kim Song; Eugene Lih; Deahyung Lee; Hong-Hee Jung
Journal:  J Funct Biomater       Date:  2019-11-16

6.  The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study.

Authors:  Yihan Li; Qingxian Tian; Kunpeng Leng; Meng Guo
Journal:  BMC Surg       Date:  2022-09-10       Impact factor: 2.030

7.  Olecranon fractures in children and adolescents: outcomes based on fracture fixation.

Authors:  C A Perkins; M T Busch; M A Christino; J Axelrod; D P Devito; J A Fabregas; J C Flanagan; J Murphy; D Olszewski; M L Schmitz; T Schrader; S C Willimon
Journal:  J Child Orthop       Date:  2018-10-01       Impact factor: 1.548

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.