Literature DB >> 12569620

Modeling O2 transport within engineered hepatic devices.

Randall E McClelland1, Jeffrey M MacDonald, Robin N Coger.   

Abstract

Predicting and improving oxygen transport within bioartificial liver (BAL) devices continues to be an important engineering challenge since oxygen is one of the critical nutrients necessary for maintaining hepatocyte viability and function. Such a computational model would not only help predict outcomes but it would also allow system modifications to be analyzed prior to developing experimental protocols. This would help to facilitate future design improvements while reducing both experimental time and capital resource costs, and is the focus of the current study. Specifically, a computational model of O(2) transport through collagen and microporous collagen ECMs is analyzed for hollow fiber (HF), flat plate (FP), and spheroid BAL designs. By modifying the O(2) boundary conditions, hepatocyte O(2) consumption levels, O(2) permeability of the ECM, and ECM void fractions, O(2) transport predictions are determined for each system as a function of time and distance. Accuracy of the predictive model is confirmed by comparing computational vs. experimental results for the HF BAL system. The model's results indicate that O(2) transport within all three BAL designs can be improved significantly by incorporating the enhancement technique. This technique modifies a diffusion-dominant gel ECM into a porous matrix with diffusive and convective flows that mutually transport O(2) through the ECMs. Although tortuous pathways increase the porous ECM's overall effective length of O(2) travel, the decreased transport resistances of these pathways allow O(2) to permeate more effectively into the ECMs. Furthermore, because the HF design employs convective flow on both its inner and outer ECM surfaces, greater control of O(2) transport through its ECM is predicted, as compared with the single O(2) source inputs of the flat plate and spheroid systems. The importance of this control is evaluated by showing how modifying the O(2) concentration and/or transfer coefficients of the convective flows can affect O(2) transport. Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 82: 12-27, 2003.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12569620     DOI: 10.1002/bit.10531

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  11 in total

Review 1.  Stable isotope-resolved metabolomics and applications for drug development.

Authors:  Teresa W-M Fan; Pawel K Lorkiewicz; Katherine Sellers; Hunter N B Moseley; Richard M Higashi; Andrew N Lane
Journal:  Pharmacol Ther       Date:  2011-12-23       Impact factor: 12.310

2.  Computational modeling of adherent cell growth in a hollow-fiber membrane bioreactor for large-scale 3-D bone tissue engineering.

Authors:  Davod Mohebbi-Kalhori; Amin Behzadmehr; Charles J Doillon; Afra Hadjizadeh
Journal:  J Artif Organs       Date:  2012-05-19       Impact factor: 1.731

3.  A 3D hybrid model for tissue growth: the interplay between cell population and mass transport dynamics.

Authors:  Gang Cheng; Pauline Markenscoff; Kyriacos Zygourakis
Journal:  Biophys J       Date:  2009-07-22       Impact factor: 4.033

4.  A microfluidic device to study cancer metastasis under chronic and intermittent hypoxia.

Authors:  Miguel A Acosta; Xiao Jiang; Pin-Kang Huang; Kyle B Cutler; Christine S Grant; Glenn M Walker; Michael P Gamcsik
Journal:  Biomicrofluidics       Date:  2014-10-17       Impact factor: 2.800

5.  Three-dimensional numerical modeling and computational fluid dynamics simulations to analyze and improve oxygen availability in the AMC bioartificial liver.

Authors:  Guy Mareels; Paul P C Poyck; Sunny Eloot; Robert A F M Chamuleau; Pascal R Verdonck
Journal:  Ann Biomed Eng       Date:  2006-10-10       Impact factor: 3.934

Review 6.  New advances in MR-compatible bioartificial liver.

Authors:  Rex E Jeffries; Jeffrey M Macdonald
Journal:  NMR Biomed       Date:  2011-02-20       Impact factor: 4.044

7.  Liver Cell Culture Devices.

Authors:  B Andria; A Bracco; G Cirino; R A F M Chamuleau
Journal:  Cell Med       Date:  2010-07-01

8.  Effect of oxygen concentration on viability and metabolism in a fluidized-bed bioartificial liver using ³¹P and ¹³C NMR spectroscopy.

Authors:  Rex E Jeffries; Michael P Gamcsik; Kayvan R Keshari; Peter Pediaditakis; Andrey P Tikunov; Gregory B Young; Haakil Lee; Paul B Watkins; Jeffrey M Macdonald
Journal:  Tissue Eng Part C Methods       Date:  2012-09-28       Impact factor: 3.056

9.  Studies on the use of hollow fibre membrane bioreactors for tissue generation by using rat bone marrow fibroblastic cells and a composite scaffold.

Authors:  Hua Ye; Zhidao Xia; David J P Ferguson; James T Triffitt; Zhanfeng Cui
Journal:  J Mater Sci Mater Med       Date:  2007-04       Impact factor: 3.896

10.  Present and Future Developments in Hepatic Tissue Engineering for Liver Support Systems : State of the art and future developments of hepatic cell culture techniques for the use in liver support systems.

Authors:  Sonja Diekmann; Augustinus Bader; Stephanie Schmitmeier
Journal:  Cytotechnology       Date:  2006-06-23       Impact factor: 2.058

View more