Interface pressure and shear stress changes with amputee weight loss: case studies from two trans-tibial amputee subjects.

J E Sanders1, J R Fergason, S G Zachariah, A K Jacobsen.   

Abstract

Interface pressures and shear stresses were measured at monthly intervals on two trans-tibial amputee subjects who lost more than 12% of their body weight over the course of the study. For one subject interface pressures and shear stresses during the weight-acceptance phase of gait decreased over the study interval at all 13 sites monitored, while the other subject experienced increased pressures distally but decreased pressures proximally. Subjects' stumps appeared to atrophy over the study interval, increasing distal end and patellar tendon loading, but not increasing interface shear stresses at other locations. Adding socks at the end of the study did not return interface pressures to first session values at all sites. It is expected that local stump shape changes occurred, causing a non-uniform change in interface stress patterns.

Entities:  

Mesh:

Year:  2002        PMID: 12562072     DOI: 10.1080/03093640208726654

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  5 in total

1.  Comparison of Rectified and Unrectified Sockets for Transtibial Amputees.

Authors:  Jack R Engsberg; S Wayne Sprouse; Mary L Uhrich; Barbara R Ziegler; F Daniel Luitjohan
Journal:  J Prosthet Orthot       Date:  2008

2.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

3.  An Inductive Sensing System to Measure In-Socket Residual Limb Displacements for People Using Lower-Limb Prostheses.

Authors:  Katrina M Henrikson; Ethan J Weathersby; Brian G Larsen; John C Cagle; Jake B McLean; Joan E Sanders
Journal:  Sensors (Basel)       Date:  2018-11-09       Impact factor: 3.576

Review 4.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

Review 5.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  5 in total