OBJECTIVES: To correlate anatomic, procedural, and dosimetric parameters with the rate of intermittent self-catheterization (ISC). METHODS: The records of 402 patients with a median age of 69 years treated with 125I prostate seed implantation from 1996 to 2001 were reviewed for the use of ISC. The records were examined for the preimplant factors: prostate volume, use of androgen deprivation, and prostate length. The intraprocedural factor reviewed was the number of needles used. The following postimplant information was also collected: preimplant transrectal ultrasound-generated prostate volume/postimplant computed tomography-generated prostate volume ratio, V100, V150, V200, V300, V400, D90, and D100. Correlation was assessed using logistic regression analysis. RESULTS: Forty-four patients had to use ISC (10.9%). The mean and median duration of ISC was 11.9 and 6 weeks, respectively. From univariate analysis, prostate length and prostate volume were found to be statistically significant predictors of ISC after 125I prostate seed implantation with a P value of 0.0002 and 0.0042, respectively. With multivariate analysis, only prostate length was a statistically significant predictor of ISC use after 125I prostate seed implantation (P = 0.0095). CONCLUSIONS: Prostate length is an important predictor of ISC after 125I prostate seed implantation.
OBJECTIVES: To correlate anatomic, procedural, and dosimetric parameters with the rate of intermittent self-catheterization (ISC). METHODS: The records of 402 patients with a median age of 69 years treated with 125I prostate seed implantation from 1996 to 2001 were reviewed for the use of ISC. The records were examined for the preimplant factors: prostate volume, use of androgen deprivation, and prostate length. The intraprocedural factor reviewed was the number of needles used. The following postimplant information was also collected: preimplant transrectal ultrasound-generated prostate volume/postimplant computed tomography-generated prostate volume ratio, V100, V150, V200, V300, V400, D90, and D100. Correlation was assessed using logistic regression analysis. RESULTS: Forty-four patients had to use ISC (10.9%). The mean and median duration of ISC was 11.9 and 6 weeks, respectively. From univariate analysis, prostate length and prostate volume were found to be statistically significant predictors of ISC after 125I prostate seed implantation with a P value of 0.0002 and 0.0042, respectively. With multivariate analysis, only prostate length was a statistically significant predictor of ISC use after 125I prostate seed implantation (P = 0.0095). CONCLUSIONS: Prostate length is an important predictor of ISC after 125I prostate seed implantation.
Authors: Samuel T Chao; Kenneth Angermeier; Eric A Klein; Chandana A Reddy; James C Ulchaker; Andrew Stephenson; Steven Campbell; Jay P Ciezki Journal: J Contemp Brachytherapy Date: 2011-03-31