Literature DB >> 12552611

Molecular imaging in small animals--roles for micro-CT.

Erik L Ritman1.   

Abstract

X-ray micro-CT is currently used primarily to generate 3D images of micro-architecture (and the function that can be deduced from it) and the regional distribution of administered radiopaque indicators, within intact rodent organs or biopsies from large animals and humans. Current use of X-ray micro-CT can be extended in three ways to increase the quantitative imaging of molecular transport and accumulation within such specimens. (1) By use of heavy elements, other than the usual iodine, attached to molecules of interest or to surrogates for those molecules. The accumulation of the indicator in the physiological compartments, and the transport to and from such compartments, can be quantitated from the imaged spatial distribution of these contrast agents. (2) The high spatial resolution of conventional X-ray attenuation-based CT images can be used to improve the quantitative nature of radionuclide-based tomographic images (SPECT & PET) by providing correction for attenuation of the emitted gamma rays and the accurate delineation of physiological spaces known to selectively accumulate those indicators. Similarly, other imaging modalities which also localize functions in 2D images (such as histological sections subsequently obtained from the same specimen), can provide a synergistic combination with CT-based 3D microstructure. (3) By increasing the sensitivity and specificity of X-ray CT image contrast by use of methods such as: K-edge subtraction imaging, X-ray fluorescence imaging, imaging of the various types of scattered X-ray and the consequences of the change in the speed of X-rays through different tissues, such as refraction and phase shift. These other methods of X-ray imaging can increase contrast by more than an order of magnitude over that due to conventionally-used attenuation of X-ray. To fully exploit their potentials, much development of radiopaque indicators, scanner hardware and image reconstruction and analysis software will be needed. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12552611     DOI: 10.1002/jcb.10415

Source DB:  PubMed          Journal:  J Cell Biochem Suppl        ISSN: 0733-1959


  33 in total

1.  beta-Catenin initiates tooth neogenesis in adult rodent incisors.

Authors:  F Liu; S Dangaria; T Andl; Y Zhang; A C Wright; M Damek-Poprawa; S Piccolo; A Nagy; M M Taketo; T G H Diekwisch; S O Akintoye; S E Millar
Journal:  J Dent Res       Date:  2010-06-08       Impact factor: 6.116

2.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

3.  Investigation of microstructural features in regenerating bone using micro computed tomography.

Authors:  A C Jones; A Sakellariou; A Limaye; C H Arns; T J Senden; T Sawkins; M A Knackstedt; D Rohner; D W Hutmacher; A Brandwood; B K Milthorpe
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

4.  Algorithm-enabled low-dose micro-CT imaging.

Authors:  Xiao Han; Junguo Bian; Diane R Eaker; Timothy L Kline; Emil Y Sidky; Erik L Ritman; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2010-10-25       Impact factor: 10.048

Review 5.  [Molecular imaging: future uses in arthritides].

Authors:  M H Brem; P M Schlechtweg; J Mackenzie; C S Winalski; P Lang
Journal:  Radiologe       Date:  2006-05       Impact factor: 0.635

Review 6.  Small animal imaging facility: new perspectives for the radiologist.

Authors:  R Grassi; C Cavaliere; S Cozzolino; L Mansi; S Cirillo; G Tedeschi; R Franchi; P Russo; S Cornacchia; A Rotondo
Journal:  Radiol Med       Date:  2008-12-11       Impact factor: 3.469

7.  Possibilities and limits of X-ray microtomography for in vivo and ex vivo detection of vascular calcifications.

Authors:  A A Postnov; P C D'Haese; E Neven; N M De Clerck; V P Persy
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-11       Impact factor: 2.357

8.  Small-animal CT - Its Difference from, and Impact on, Clinical CT.

Authors:  Erik L Ritman
Journal:  Nucl Instrum Methods Phys Res A       Date:  2007-10-01       Impact factor: 1.455

9.  Single-walled carbon nanotubes as a multimodal-thermoacoustic and photoacoustic-contrast agent.

Authors:  Manojit Pramanik; Magdalena Swierczewska; Danielle Green; Balaji Sitharaman; Lihong V Wang
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

10.  Site-specific effects of PECAM-1 on atherosclerosis in LDL receptor-deficient mice.

Authors:  Reema Goel; Benjamin R Schrank; Shikha Arora; Brian Boylan; Barbara Fleming; Hiroto Miura; Peter J Newman; Robert C Molthen; Debra K Newman
Journal:  Arterioscler Thromb Vasc Biol       Date:  2008-07-31       Impact factor: 8.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.