Small-animal CT - Its Difference from, and Impact on, Clinical CT.

Erik L Ritman1.   

Abstract

For whole-body CT images of small rodents, a voxel resolution of at least 10(-3) mm(3) is needed for scale-equivalence to that currently achieved in clinical CT scanners (∼1 mm(3)) in adult humans. These "mini-CT" images generally require minutes rather than seconds to complete a scan. The radiation exposure resulting from these mini-CT scans, while higher than clinical CT scans, is below the level resulting in acute tissue damage. Hence, these scans are useful for performing clinical-type diagnostic and monitoring scans for animal models of disease and their response to treatment. "Micro-CT", with voxel size <10(-5) mm(3), has been useful for imaging isolated, intact organs at an almost cellular level of resolution. Micro-CT has the great advantage over traditional microscopic methods in that it generates detailed 3D images in relatively large, opaque, volumes such as an intact rodent heart or kidney. The radiation exposure needed in these scans results in acute tissue damage if used in living animals.Experience with micro-CT is contributing to exploration of new applications for clinical CT imaging by providing insights into different modes of x-ray image formation as follows:Spatial resolution should be sufficient to detect an individual Basic Functional Unit (BFU, the smallest collection of diverse cells, such as hepatic lobule, that behaves like the organ), which requires voxels ∼10(-3) mm(3) in volume, so that the BFUs can be counted.Contrast resolution sufficient to allow quantitation of:New microvascular growth, which manifests as increased tissue contrast due to x-ray contrast agent in those vessels' lumens during passage of injected contrast agent in blood.Impaired endothelial integrity which manifests as increased opacification and delayed washout of contrast from tissues.Discrimination of pathological accumulations of metals such as Fe and Ca, which occur in the arterial wall following hemorrhage or tissue damage.Micro-CT can also be used as a test bed for exploring the utility of several modes of x-ray image formation, such as the use of dual energy x-ray subtraction, x-ray scatter, phase delay and refraction-based imaging for increasing the contrast amongst soft tissue components. With the recent commercial availability of high speed, multi-slice CT scanners which can be operated in dual energy mode, some of these micro-CT scanner capabilities and insights are becoming implementable in those CT scanners. As a result, the potential diagnostic spectrum that can be addressed with those scanners is broadened considerably.

Entities:  

Year:  2007        PMID: 18836514      PMCID: PMC2128617          DOI: 10.1016/j.nima.2007.06.040

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  8 in total

1.  In vivo micro tomography.

Authors:  A Kohlbrenner; B Koller; S Hämmerle; P Rüegsegger
Journal:  Adv Exp Med Biol       Date:  2001       Impact factor: 2.622

2.  Micro-CT imaging of structure-to-function relationship of bone microstructure and associated vascular involvement.

Authors:  E L Ritman; M E Bolander; L A Fitzpatrick; R T Turner
Journal:  Technol Health Care       Date:  1998-12       Impact factor: 1.285

3.  Cryostatic micro-computed tomography imaging of arterial wall perfusion.

Authors:  Birgit Kantor; Steven M Jorgensen; Patricia E Lund; Michael S Chmelik; Denise A Reyes; Erik L Ritman
Journal:  Scanning       Date:  2002 Jul-Aug       Impact factor: 1.932

Review 4.  Molecular imaging in small animals--roles for micro-CT.

Authors:  Erik L Ritman
Journal:  J Cell Biochem Suppl       Date:  2002

5.  Electron density measurement with dual-energy x-ray CT using synchrotron radiation.

Authors:  Masami Torikoshi; Takanori Tsunoo; Makoto Sasaki; Masahiro Endo; Yutaka Noda; Yumiko Ohno; Toshiyuki Kohno; Kazuyuki Hyodo; Kentaro Uesugi; Naoto Yagi
Journal:  Phys Med Biol       Date:  2003-03-07       Impact factor: 3.609

6.  Ultrahigh-Resolution X-ray Tomography.

Authors:  W S Haddad; I McNulty; J E Trebes; E H Anderson; R A Levesque; L Yang
Journal:  Science       Date:  1994-11-18       Impact factor: 47.728

7.  X-ray microtomography (microCT) using phase contrast for the investigation of organic matter.

Authors:  F Beckmann; U Bonse; F Busch; O Günnewig
Journal:  J Comput Assist Tomogr       Date:  1997 Jul-Aug       Impact factor: 1.826

8.  Noise due to photon counting statistics in computed X-ray tomography.

Authors:  D A Chesler; S J Riederer; N J Pelc
Journal:  J Comput Assist Tomogr       Date:  1977-01       Impact factor: 1.826

  8 in total
  19 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

Review 2.  Nanotechnology for computed tomography: a real potential recently disclosed.

Authors:  Nicolas Anton; Thierry F Vandamme
Journal:  Pharm Res       Date:  2013-07-30       Impact factor: 4.200

3.  Remodeling of alveolar septa after murine pneumonectomy.

Authors:  Alexandra B Ysasi; Willi L Wagner; Robert D Bennett; Maximilian Ackermann; Cristian D Valenzuela; Janeil Belle; Akira Tsuda; Moritz A Konerding; Steven J Mentzer
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2015-04-10       Impact factor: 5.464

Review 4.  Whole animal imaging.

Authors:  Gurpreet Singh Sandhu; Luis Solorio; Ann-Marie Broome; Nicolas Salem; Jeff Kolthammer; Tejas Shah; Chris Flask; Jeffrey L Duerk
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2010 Jul-Aug

5.  Micro computed tomography for vascular exploration.

Authors:  Lyubomir Zagorchev; Pierre Oses; Zhen W Zhuang; Karen Moodie; Mary Jo Mulligan-Kehoe; Michael Simons; Thierry Couffinhal
Journal:  J Angiogenes Res       Date:  2010-03-05

Review 6.  Recent advances in small-animal cardiovascular imaging.

Authors:  Benjamin M W Tsui; Dara L Kraitchman
Journal:  J Nucl Med       Date:  2009-04-16       Impact factor: 10.057

Review 7.  In vivo small-animal imaging using micro-CT and digital subtraction angiography.

Authors:  C T Badea; M Drangova; D W Holdsworth; G A Johnson
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

8.  Imaging technologies for preclinical models of bone and joint disorders.

Authors:  Jordi L Tremoleda; Magdy Khalil; Luke L Gompels; Marzena Wylezinska-Arridge; Tonia Vincent; Willy Gsell
Journal:  EJNMMI Res       Date:  2011-07-29       Impact factor: 3.138

9.  In vivo diagnostic imaging using micro-CT: sequential and comparative evaluation of rodent models for hepatic/brain ischemia and stroke.

Authors:  Naoto Hayasaka; Nobuo Nagai; Naoyuki Kawao; Atsuko Niwa; Yoshichika Yoshioka; Yuki Mori; Hiroshi Shigeta; Nobuo Kashiwagi; Masaaki Miyazawa; Takao Satou; Hideaki Higashino; Osamu Matsuo; Takamichi Murakami
Journal:  PLoS One       Date:  2012-02-23       Impact factor: 3.240

10.  18F-Fluoride Signal Amplification Identifies Microcalcifications Associated With Atherosclerotic Plaque Instability in Positron Emission Tomography/Computed Tomography Images.

Authors:  Michael D Creager; Tobias Hohl; Joshua D Hutcheson; Alastair J Moss; Florian Schlotter; Mark C Blaser; Mi-Ae Park; Lang Ho Lee; Sasha A Singh; Carlos J Alcaide-Corral; Adriana A S Tavares; David E Newby; Marie F Kijewski; Masanori Aikawa; Marcelo Di Carli; Marc R Dweck; Elena Aikawa
Journal:  Circ Cardiovasc Imaging       Date:  2019-01       Impact factor: 7.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.