Literature DB >> 12549233

Fully automated registration and warping of contrast-enhanced first-pass perfusion images.

Caterina M Gallippi1, Christopher M Kramer, Yong-Lin Hu, Diane A Vido, Nathaniel Reichek, Walter J Rogers.   

Abstract

Respiratory motion during acquisition of first-pass myocardial perfusion images results in translation, distortion from out-of-plane motion, and changes in left ventricular geometry. Together these effects make visual image analysis more difficult and limit methods of quantitative analysis of contrast kinetics. We present a fully automated registration and warping algorithm for correcting translation and geometric distortions using a statistically based image registration method. Twelve patients (mean age 51 +/- 12 years) were studied 3 +/- 1 days after reperfused first myocardial infarction. Perfusion images were acquired during bolus administration of nonionic Gd-DTPA. Pixel intensity statistics were computed for each image in the neighborhood of high spatial frequencies. These statistics were then used to register and warp each target image (image to be registered and warped) to a common template image. Average image-to-image vertical translation was 2.6 +/- 0.8 pixels (3.4 +/- 1.0 mm) prior to processing and 0.9 +/- 0.3 pixels (1.2 +/- 0.4 mm) post-processing (P < 0.0001). Mean image-to-image horizontal translation was 1.7 +/- 1.2 pixels (1.8 +/- 1.2 mm) before and 1.3 +/- 0.7 pixels (1.4 +/- 0.7 mm) after processing (P = 0.05). Left ventricular endocardial area varied an average of 105 +/- 55 pixels (140.7 +/- 53.7 mm2) between images prior to processing vs. 51 +/- 15 pixels (68.3 +/- 20.1 mm2) after processing (P < 0.001). Thus automated, statistically based registration and warping of perfusion images is effective in reducing image-to-image translation. This method may permit more sensitive qualitative and quantitative evaluation of myocardial contrast-enhanced first-pass images.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12549233     DOI: 10.1081/jcmr-120016384

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  4 in total

1.  Color-encoded semiautomatic analysis of multi-slice first-pass magnetic resonance perfusion: comparison to tetrofosmin single photon emission computed tomography perfusion and X-ray angiography.

Authors:  Holger Thiele; Sven Plein; Marcel Breeuwer; John P Ridgway; David Higgins; Penelope J Thorley; Gerhard Schuler; Mohan U Sivananthan
Journal:  Int J Cardiovasc Imaging       Date:  2004-10       Impact factor: 2.357

2.  Registration of dynamic contrast-enhanced MRI of the common carotid artery using a fixed-frame template-based squared-difference method.

Authors:  Sarayu Ramachandran; Claudia Calcagno; Venkatesh Mani; Philip M Robson; Zahi A Fayad
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

3.  Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI.

Authors:  Michael A Bush; Rizwan Ahmad; Ning Jin; Yingmin Liu; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2019-02-14       Impact factor: 4.668

4.  Non-rigid registration and KLT filter to improve SNR and CNR in GRE-EPI myocardial perfusion imaging.

Authors:  Georgeta Mihai; Yu Ding; Hui Xue; Yiu-Cho Chung; Sanjay Rajagopalan; Jens Guehring; Orlando P Simonetti
Journal:  J Biomed Sci Eng       Date:  2012-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.