Literature DB >> 12548443

Accuracy of image fusion of normal upper abdominal organs visualized with PET/CT.

Yuji Nakamoto1, Mitsuaki Tatsumi, Christian Cohade, Medhat Osman, Laura T Marshall, Richard L Wahl.   

Abstract

Although PET/CT scanners have the potential for precise fused registration of structures visualized on both PET and CT, physiological motion during the acquisition of both studies may alter the appearance of organ shape, size or location. The degree of possible mismatch in abdominal organ size and position between PET and CT has not been evaluated. The aim of this study was to assess the consistency in location and measured size of upper abdominal organs with PET and CT using a combined PET/CT system. Forty-six consecutive inpatients who underwent clinical PET/CT scans for suspected cancer were evaluated. CT and PET images attenuation corrected by both CT and germanium-68 transmission scans were obtained, and we separately determined the location of the top and bottom (height), anterior and posterior margins (thickness), and right and left margins (width) for each organ, including liver, spleen, and bilateral kidneys, using CT and both sets of PET images. Differences between the two modalities in terms of location and measured organ size were investigated. In the upper margin of the liver and lower margin of the spleen, more than 10% of the cases showed a larger discrepancy (>20 mm) between CT-based and Ge-corrected PET-based measurements, although the differences in the positions of the edges were less than 10 mm in most cases. The center of the liver tended to be located cephalad and to the right of the body, and that of the spleen tended to be cephalad and posterior on PET, as compared with CT. Moreover, the center of both kidneys tended to be seen cephalad, posterior, and to the right on PET. The liver appeared slightly larger on PET than CT in thickness (CT vs CT-corrected PET vs Ge-corrected PET = 156 mm vs 162 mm vs 162 mm) and width (186 mm vs 189 mm vs 188 mm). By contrast, the spleen appeared slightly smaller on PET than CT in height (84 mm vs 77 mm vs 80 mm) and width (85 mm vs 81 mm vs 80 mm). A similar tendency was observed in the left kidney (105 mm vs 100 mm vs 99 mm in height, and 64 mm vs 59 mm vs 58 mm in width) and the right kidney (99 mm vs 93 mm vs 93 mm in height, and 64 mm vs 59 mm vs 60 mm in width). These differences between the two modalities were statistically significant ( P<0.05). In conclusion, minor mismatches in location and organ size were found to exist between CT and PET images, in part due to physiological motion. Although these differences could potentially affect the quality of the image registrations, they were generally of a modest nature.

Entities:  

Mesh:

Year:  2003        PMID: 12548443     DOI: 10.1007/s00259-002-1080-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  15 in total

1.  PET-CT-guided percutaneous puncture of an infected cyst in autosomal dominant polycystic kidney disease: case report.

Authors:  A H Kaim; C Burger; C C Ganter; G W Goerres; E Kamel; D Weishaupt; E Dizendorf; A Schaffner; G K von Schulthess
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

Review 2.  Positron emission tomography imaging in oncology.

Authors:  D Delbeke; W H Martin
Journal:  Radiol Clin North Am       Date:  2001-09       Impact factor: 2.303

3.  Implications of respiratory motion for the quantification of 2D MR spectroscopic imaging data in the abdomen.

Authors:  A J Schwarz; M O Leach
Journal:  Phys Med Biol       Date:  2000-08       Impact factor: 3.609

4.  Respiratory kinematics of the upper abdominal organs: a quantitative study.

Authors:  H W Korin; R L Ehman; S J Riederer; J P Felmlee; R C Grimm
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

5.  Assessment of hepatic respiratory excursion.

Authors:  P H Weiss; J M Baker; E J Potchen
Journal:  J Nucl Med       Date:  1972-10       Impact factor: 10.057

6.  Cranio-caudal movements of the liver, pancreas and kidneys in respiration.

Authors:  I Suramo; M Päivänsalo; V Myllylä
Journal:  Acta Radiol Diagn (Stockh)       Date:  1984

7.  Combined PET/CT Imaging in Oncology. Impact on Patient Management.

Authors:  P G. Kluetz; C C. Meltzer; V L. Villemagne; P E. Kinahan; S Chander; M A. Martinelli; D W. Townsend
Journal:  Clin Positron Imaging       Date:  2000-11

Review 8.  PET imaging in oncology.

Authors:  R Bar-Shalom; A Y Valdivia; M D Blaufox
Journal:  Semin Nucl Med       Date:  2000-07       Impact factor: 4.446

9.  Comparison of the liver's respiratory motion in the supine and upright positions: concise communication.

Authors:  G Harauz; M J Bronskill
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

10.  Efficient stereospecific synthesis of no-carrier-added 2-[18F]-fluoro-2-deoxy-D-glucose using aminopolyether supported nucleophilic substitution.

Authors:  K Hamacher; H H Coenen; G Stöcklin
Journal:  J Nucl Med       Date:  1986-02       Impact factor: 10.057

View more
  12 in total

1.  Clinical evaluation of a breathing protocol for PET/CT.

Authors:  Ramon de Juan; Burkhardt Seifert; Thomas Berthold; Gustav K von Schulthess; Gerhard W Goerres
Journal:  Eur Radiol       Date:  2003-12-16       Impact factor: 5.315

Review 2.  PET/CT: a new imaging technology in nuclear medicine.

Authors:  Heiko Schöder; Yusuf E Erdi; Steven M Larson; Henry W D Yeung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-05       Impact factor: 9.236

3.  Correlation between respiration-induced thoracic expansion and a shift of central structures.

Authors:  M Weckesser; L Stegger; K U Juergens; D Wormanns; W Heindel; O Schober
Journal:  Eur Radiol       Date:  2005-12-21       Impact factor: 5.315

4.  Respiratory-induced errors in tumor quantification and delineation in CT attenuation-corrected PET images: effects of tumor size, tumor location, and respiratory trace: a simulation study using the 4D XCAT phantom.

Authors:  Parham Geramifar; Mojtaba Shamsaie Zafarghandi; Pardis Ghafarian; Arman Rahmim; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2013-12       Impact factor: 3.488

5.  Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions.

Authors:  Loïc Fin; Joël Daouk; Julie Morvan; Pascal Bailly; Isabelle El Esper; Lazhar Saidi; Marc-Etienne Meyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

6.  Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source.

Authors:  Dimitri Papathanassiou; Stéphanie Becker; Roland Amir; Benoît Menéroux; Jean-Claude Liehn
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-08-31       Impact factor: 9.236

7.  Non-malignant FDG uptake in infradiaphragmatic adipose tissue: a new site of physiological tracer biodistribution characterised by PET/CT.

Authors:  Rachel Bar-Shalom; Diana Gaitini; Zohar Keidar; Ora Israel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-09       Impact factor: 9.236

Review 8.  FDG-PET/CT imaging findings of hepatic tumors and tumor-like lesions based on molecular background.

Authors:  Kumi Ozaki; Kenichi Harada; Noboru Terayama; Nobuyuki Kosaka; Hirohiko Kimura; Toshifumi Gabata
Journal:  Jpn J Radiol       Date:  2020-04-03       Impact factor: 2.374

9.  Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: review and perspective.

Authors:  Stephen R Bowen; Matthew J Nyflot; Michael Gensheimer; Kristi R G Hendrickson; Paul E Kinahan; George A Sandison; Shilpen A Patel
Journal:  Clin Transl Med       Date:  2012-08-31

10.  The future of hybrid imaging-part 2: PET/CT.

Authors:  Thomas Beyer; David W Townsend; Johannes Czernin; Lutz S Freudenberg
Journal:  Insights Imaging       Date:  2011-02-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.