Literature DB >> 12548274

A study of the Bispectral Index Monitor during procedural sedation and analgesia in the emergency department.

Michelle Gill1, Steven M Green, Baruch Krauss.   

Abstract

STUDY
OBJECTIVE: The Bispectral Index Monitor has been validated as an objective measure of sedation depth in the operating room; however, its value for states other than general anesthesia remains unclear. We hypothesized that bispectral index monitoring would reliably correlate with traditional definitions of sedation depth in emergency department patients undergoing procedural sedation and analgesia.
METHODS: In this prospective observational study we measured the Bispectral Index score and a modified Ramsay Sedation Scale score every 5 minutes in a convenience sample of adult ED patients undergoing procedural sedation and analgesia. Investigators and treating physicians were blinded to Bispectral Index scores, which were later correlated with modified Ramsay Sedation Scale scores. We constructed receiver operating characteristic curves to determine the most discriminatory Bispectral Index score thresholds for sedation depth.
RESULTS: Two hundred seventy paired readings were obtained from 37 patients. Despite being statistically significant (P <.0005), the correlation between the Bispectral Index Monitor and modified Ramsay Sedation Scale scores was only moderate (Spearman rho=-0.690) and displayed wide variability. A modified Ramsay Sedation Scale score consistent with mild-to-moderate sedation corresponded to Bispectral Index scores of 34 (general anesthesia) to 98 (fully awake), whereas a modified Ramsay Sedation Scale score consistent with deep sedation corresponded to Bispectral Index scores of 40 to 98. Areas under receiver operating characteristic curves demonstrated moderate (0.83 to 0.86) discriminatory power at all modified Ramsay Sedation Scale thresholds, with the exception of a modified Ramsay Sedation Scale score of 7 or less, which demonstrated high discriminatory power (0.95). A Bispectral Index score of greater than 83 reliably excluded general anesthesia, and a Bispectral Index score of 70 or less reliably identified general anesthesia.
CONCLUSION: Bispectral index monitoring reliably predicted patients undergoing procedural sedation and analgesia who were sedated to the point of general anesthesia from those with lesser degrees of sedation but did not discriminate mild-to-moderate sedation or moderate-to-deep sedation, as measured by the Ramsay Sedation Scale score for the patients undergoing procedural sedation and analgesia in our ED.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12548274     DOI: 10.1067/mem.2003.53

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  11 in total

1.  Do palliative care patients and relatives think it would be acceptable to use Bispectral index (BIS) technology to monitor palliative care patients' levels of consciousness? A qualitative exploration with interviews and focus groups for the I-CAN-CARE research programme.

Authors:  Anna-Maria Krooupa; Patrick Stone; Stephen McKeever; Kathy Seddon; Sarah Davis; Elizabeth L Sampson; Adrian Tookman; Jonathan Martin; Vinnie Nambisan; Bella Vivat
Journal:  BMC Palliat Care       Date:  2022-05-24       Impact factor: 3.113

Review 2.  [Procedural analgesia : concepts and practice].

Authors:  F Heid; M Gerth; W Roth; M Hessmann; C Werner
Journal:  Chirurg       Date:  2008-08       Impact factor: 0.955

3.  Pediatric procedural sedation and analgesia.

Authors:  James R Meredith; Kelly P O'Keefe; Sagar Galwankar
Journal:  J Emerg Trauma Shock       Date:  2008-07

4.  Recall after procedural sedation in the emergency department.

Authors:  Alex Swann; Jeffrey Williams; Daniel M Fatovich
Journal:  Emerg Med J       Date:  2007-05       Impact factor: 2.740

5.  Anesthesia-induced loss of consciousness disrupts auditory responses beyond primary cortex.

Authors:  Aaron J Krom; Amit Marmelshtein; Hagar Gelbard-Sagiv; Ariel Tankus; Hanna Hayat; Daniel Hayat; Idit Matot; Ido Strauss; Firas Fahoum; Martin Soehle; Jan Boström; Florian Mormann; Itzhak Fried; Yuval Nir
Journal:  Proc Natl Acad Sci U S A       Date:  2020-05-12       Impact factor: 11.205

6.  A comparison of ketamine-midazolam and ketamine-propofol combinations used for sedation in the endobronchial ultrasound-guided transbronchial needle aspiration: a prospective, single-blind, randomized study.

Authors:  Tülay Dal; Hilal Sazak; Mehtap Tunç; Saziye Sahin; Aydın Yılmaz
Journal:  J Thorac Dis       Date:  2014-06       Impact factor: 2.895

7.  Procedural sedation: A review of sedative agents, monitoring, and management of complications.

Authors:  Joseph D Tobias; Marc Leder
Journal:  Saudi J Anaesth       Date:  2011-10

8.  Prediction of Nociceptive Responses during Sedation by Linear and Non-Linear Measures of EEG Signals in High Frequencies.

Authors:  Umberto Melia; Montserrat Vallverdú; Xavier Borrat; Jose Fernando Valencia; Mathieu Jospin; Erik Weber Jensen; Pedro Gambus; Pere Caminal
Journal:  PLoS One       Date:  2015-04-22       Impact factor: 3.240

9.  A comparative study to evaluate the effect of intranasal dexmedetomidine versus oral alprazolam as a premedication agent in morbidly obese patients undergoing bariatric surgery.

Authors:  Lakshmi Jayaraman; Aparna Sinha; Dinesh Punhani
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-04

10.  Use of Bispectral Index Score for Interventional Bronchoscopy Procedures.

Authors:  Lida Fadaizadeh; Mahsa Sadat Hoseyni; Elham Shajareh; Gholamreza Heydari; Seyed Hossein Ardehali
Journal:  Tanaffos       Date:  2015
View more