PURPOSE: We reviewed the outcome of cuff downsizing with an artificial urinary sphincter for treating recurrent incontinence due to urethral atrophy. MATERIALS AND METHODS: We analyzed the records of 17 patients in a 7-year period in whom clinical, radiological and urodynamic evidence of urethral atrophy was treated with cuff downsizing. Cuff downsizing was accomplished by removing the existing cuff and replacing it with a 4 cm. cuff within the established false capsule. Incontinence and satisfaction parameters before and after the procedure were assessed by a validated questionnaire. RESULTS: Mean patient age was 70 years (range 62 to 79). Average time to urethral atrophy was 31 months (range 5 to 96) after primary sphincter implantation. Mean followup after downsizing was 22 months (range 1 to 64). Cuff downsizing caused a mean decrease of 3.9 to 0.5 pads daily. The number of severe leakage episodes decreased from a mean of 5.4 to 2.1 The mean SEAPI (stress leakage, emptying, anatomy, protection, inhibition) score decreased from 8.2 to 2.4. Patient satisfaction increased from 15% to 80% after cuff downsizing. In 1 patient an infected cuff required complete removal of the device. CONCLUSIONS: Patient satisfaction and continence parameters improved after cuff downsizing. We believe that this technique is a simple and effective method of restoring continence after urethral atrophy.
PURPOSE: We reviewed the outcome of cuff downsizing with an artificial urinary sphincter for treating recurrent incontinence due to urethral atrophy. MATERIALS AND METHODS: We analyzed the records of 17 patients in a 7-year period in whom clinical, radiological and urodynamic evidence of urethral atrophy was treated with cuff downsizing. Cuff downsizing was accomplished by removing the existing cuff and replacing it with a 4 cm. cuff within the established false capsule. Incontinence and satisfaction parameters before and after the procedure were assessed by a validated questionnaire. RESULTS: Mean patient age was 70 years (range 62 to 79). Average time to urethral atrophy was 31 months (range 5 to 96) after primary sphincter implantation. Mean followup after downsizing was 22 months (range 1 to 64). Cuff downsizing caused a mean decrease of 3.9 to 0.5 pads daily. The number of severe leakage episodes decreased from a mean of 5.4 to 2.1 The mean SEAPI (stress leakage, emptying, anatomy, protection, inhibition) score decreased from 8.2 to 2.4. Patient satisfaction increased from 15% to 80% after cuff downsizing. In 1 patient an infected cuff required complete removal of the device. CONCLUSIONS:Patient satisfaction and continence parameters improved after cuff downsizing. We believe that this technique is a simple and effective method of restoring continence after urethral atrophy.
Authors: Roger K Khouri; Nicolas M Ortiz; Benjamin M Dropkin; Gregory A Joice; Adam S Baumgarten; Allen F Morey; Steven J Hudak Journal: Curr Urol Rep Date: 2021-03-29 Impact factor: 3.092
Authors: Brian J Linder; Boyd R Viers; Matthew J Ziegelmann; Marcelino E Rivera; Daniel S Elliott Journal: Int Braz J Urol Date: 2017 Mar-Apr Impact factor: 1.541