Literature DB >> 12541096

On-line noninvasive one-point measurements of pulse wave velocity.

Akimitsu Harada1, Takashi Okada, Kiyomi Niki, Dehua Chang, Motoaki Sugawara.   

Abstract

Pulse wave velocity (PWV) is a basic parameter in the dynamics of pressure and flow waves traveling in arteries. Conventional on-line methods of measuring PWV have mainly been based on "two-point" measurements, i.e., measurements of the time of travel of the wave over a known distance. This paper describes two methods by which on-line "one-point" measurements can be made, and compares the results obtained by the two methods. The principle of one method is to measure blood pressure and velocity at a point, and use the water-hammer equation for forward traveling waves. The principle of the other method is to derive PWV from the stiffness parameter of the artery. Both methods were realized by using an ultrasonic system which we specially developed for noninvasive measurements of wave intensity. We applied the methods to the common carotid artery in 13 normal humans. The regression line of the PWV (m/s) obtained by the former method on the PWV (m/s) obtained by the latter method was y = 1.03x - 0.899 (R(2) = 0.83). Although regional PWV in the human carotid artery has not been reported so far, the correlation between the PWVs obtained by the present two methods was so high that we are convinced of the validity of these methods.

Entities:  

Mesh:

Year:  2002        PMID: 12541096     DOI: 10.1007/s003800200045

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  28 in total

1.  Evaluation of carotid wave intensity in firefighters following firefighting.

Authors:  Huimin Yan; Christopher A Fahs; Sushant Ranadive; Lindy M Rossow; Abbi D Lane; Stamatis Agiovlasitis; George Echols; Denise Smith; Gavin P Horn; Thomas Rowland; Bo Fernhall
Journal:  Eur J Appl Physiol       Date:  2011-10-29       Impact factor: 3.078

2.  Effects of cold pressor-induced sympathetic stimulation on the mechanical properties of common carotid and femoral arteries in healthy males.

Authors:  Jie Liu; Tie-Sheng Cao; Yun-You Duan; Yi-Lin Yang; Li-Jun Yuan
Journal:  Heart Vessels       Date:  2010-12-22       Impact factor: 2.037

3.  Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop.

Authors:  A W Khir; M J P Swalen; J Feng; K H Parker
Journal:  Med Biol Eng Comput       Date:  2007-08-21       Impact factor: 2.602

4.  Effects of sublingual nitroglycerin on working conditions of the heart and arterial system: analysis using wave intensity.

Authors:  Kiyomi Niki; Motoaki Sugawara; Dehua Chang; Akimitsu Harada; Takashi Okada; Rie Tanaka
Journal:  J Med Ultrason (2001)       Date:  2005-12       Impact factor: 1.314

5.  Comparison of pulse wave velocity assessed by three different techniques: Arteriograph, Complior, and Echo-tracking.

Authors:  Diana J Mihalcea; Maria Florescu; Berenice M C Suran; Oana A Enescu; Raluca I Mincu; Stefania Magda; Natalia Patrascu; Dragos Vinereanu
Journal:  Heart Vessels       Date:  2015-01-30       Impact factor: 2.037

6.  Reference values of one-point carotid stiffness parameters determined by carotid echo-tracking and brachial pulse pressure in a large population of healthy subjects.

Authors:  Olga Vriz; Victor Aboyans; Rosalba Minisini; Julien Magne; Nicole Bertin; Mario Pirisi; Eduardo Bossone
Journal:  Hypertens Res       Date:  2017-03-02       Impact factor: 3.872

7.  Non-invasive one-point carotid wave intensity in a large group of healthy subjects: A ventricular-arterial coupling parameter.

Authors:  Olga Vriz; Concetta Zito; Vitantonio di Bello; Salvatore La Carrubba; Caterina Driussi; Scipione Carerj; Eduardo Bossone; Francesco Antonini-Canterin
Journal:  Heart Vessels       Date:  2014-12-18       Impact factor: 2.037

8.  Validity of the Water Hammer Formula for Determining Regional Aortic Pulse Wave Velocity: Comparison of One-Point and Two-Point (Foot-to-Foot) Measurements Using a Multisensor Catheter in Human.

Authors:  Shizuo Hanya
Journal:  Ann Vasc Dis       Date:  2013-05-30

9.  Measurement of biaxial mechanical properties of soft tubes and arteries using piezoelectric elements and sonometry.

Authors:  Miguel Bernal; Matthew W Urban; Daniel Rosario; Wilkins Aquino; James F Greenleaf
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

10.  Clinical usefulness of wave intensity analysis.

Authors:  Motoaki Sugawara; Kiyomi Niki; Nobuyuki Ohte; Takashi Okada; Akimitsu Harada
Journal:  Med Biol Eng Comput       Date:  2008-09-02       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.