Literature DB >> 12540439

Sonography of the medial collateral ligament of the elbow: a study of cadavers and healthy adult male volunteers.

Sabrina I Ward1, Sharlene A Teefey, George A Paletta, William D Middleton, Charles F Hildebolt, David A Rubin, Ken Yamaguchi.   

Abstract

OBJECTIVE: We assessed the ability of high-resolution sonography to reveal the size and echogenicity of the anterior bundle of the normal medial collateral ligament of the elbow in cadavers and uninjured male volunteers.
MATERIALS AND METHODS: The anterior bundle of the medial collateral ligament in five cadaveric elbows was imaged and injected with contrast material by experienced musculoskeletal radiologists using a 12-MHz linear array transducer. Immediate ligament dissection was performed. The bilateral ligaments in 30 healthy 21- to 34-year-old male volunteers were imaged with gravitational stress. Of these, five randomly selected subjects also received approximately 5 lb (11.3 kg) of applied stress.
RESULTS: Contrast material was injected directly into all five cadaveric ligaments. The anterior bundle of the medial collateral ligament in all 30 asymptomatic male volunteers was hyperechoic in comparison with surrounding muscle and had a fibrillar pattern and fanlike shape. Its mean dimensions were 2.6 +/- 0.31 x 2.2 +/- 0.47 x 4.0 +/- 0.88 mm on the right and 2.6 +/- 0.36 x 2.1 +/- 0.42 x 4.0 +/- 0.86 mm on the left, in longitudinal short, transverse short, and transverse long axes, respectively. Differences in ligament measurements in sidedness, stress application, and hand dominance did not approach statistical (Bonferroni corrected, p > 0.01) or clinical (all differences, <0.2 mm) significance.
CONCLUSION: Radiologists can accurately use sonography to identify and measure the size of the anterior bundle of the normal medial collateral ligament of the elbow. These baseline parameters for the normal ligament may prove useful when evaluating the injured ligament.

Mesh:

Substances:

Year:  2003        PMID: 12540439     DOI: 10.2214/ajr.180.2.1800389

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Ultrasound of the elbow.

Authors:  K Finlay; M Ferri; L Friedman
Journal:  Skeletal Radiol       Date:  2004-01-09       Impact factor: 2.199

2.  Evaluation of the thickness of the medial ulnar collateral ligament in junior high and high school baseball players.

Authors:  Hideaki Nagamoto; Nobuyuki Yamamoto; Daisuke Kurokawa; Hiroyuki Takahashi; Takayuki Muraki; Minoru Tanaka; Yoichi Koike; Hirotaka Sano; Eiji Itoi
Journal:  J Med Ultrason (2001)       Date:  2014-12-19       Impact factor: 1.314

3.  Ultrasound evaluation of the ulnar collateral ligament of the elbow: Which method is most reproducible?

Authors:  Mehool Shukla; Robert Keller; Nathan Marshall; Hafeez Ahmed; Courtney Scher; Vasilios Bill Moutzouros; Marnix van Holsbeeck
Journal:  Skeletal Radiol       Date:  2017-04-20       Impact factor: 2.199

4.  A new manual method for assessing elbow valgus laxity.

Authors:  Kenji Yasui; Teruhisa Mihata; Atsushi Takeda; Chisato Watanabe; Mitsuo Kinoshita
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2012-03-19

5.  Sonography of injury of the ulnar collateral ligament of the elbow-initial experience.

Authors:  Theodore T Miller; Ronald S Adler; Lawrence Friedman
Journal:  Skeletal Radiol       Date:  2004-05-06       Impact factor: 2.199

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.