Literature DB >> 12539565

In vitro validation of tissue Doppler left ventricular regional wall velocities by using a novel balloon phantom.

Y Wu1, T Irvine, Y Mori, X Li, D J Sahn.   

Abstract

To investigate the validity and accuracy of tissue Doppler imaging (TDI) using a novel balloon phantom, validation of TDI myocardial velocity measurements has been carried out indirectly from conventional M-mode images. However it is not a true and independent gold standard. We described a new TDI validation method by using a specially developed left ventricular balloon model mounted in a water bath and constructed using two pear-shaped balloons. It was connected to a pulsatile flow pump at 8 stroke volumes (50-85 ml/beat). The displacement and velocity of the balloon walls were recorded simultaneously by video imaging and TDI on a GE-Vingmed System Five with a 5 MHz phased array probe at the highest frame rates available. Conventional M-mode and 2-D imaging verified that our balloon model mimicked the shape and wall motion of left ventricle. There was a good correlation and agreement between the maximum video excursion of the anterior and posterior walls of the phantom and the results of the temporal integration of digital distance data by TDI (Anterior wall: r = 0.97, SEE = 0.24 mm, mean +/- s = 0.04 +/- 0.24 mm; Posterior wall: r = 0.95, SEE = 0.22 mm, mean +/- s = 0.03 +/- 0.24 mm). Analysis of the velocity profile by the TDI method showed that the velocity at each measured point was correlated well with the velocity obtained from the video images (Anterior wall: r = 0.97, SEE = 0.30 mm, mean +/- s = -0.04 +/- 0.28 mm; Posterior wall: r = 0.97, SEE = 0.30 mm, mean +/- s = 0.04 +/- 0.28 mm). Our balloon model provided a new independent method for the validation of TDI data. This study demonstrated that the present TDI system is reliable for measuring wall motion distance and velocity.

Entities:  

Mesh:

Year:  2001        PMID: 12539565     DOI: 10.1007/BF02886574

Source DB:  PubMed          Journal:  J Tongji Med Univ        ISSN: 0257-716X


  12 in total

1.  Colour Doppler velocity imaging of the myocardium.

Authors:  W N McDicken; G R Sutherland; C M Moran; L N Gordon
Journal:  Ultrasound Med Biol       Date:  1992       Impact factor: 2.998

2.  Doppler estimation of left ventricular filling pressure in sinus tachycardia. A new application of tissue doppler imaging.

Authors:  S F Nagueh; I Mikati; H A Kopelen; K J Middleton; M A Quiñones; W A Zoghbi
Journal:  Circulation       Date:  1998-10-20       Impact factor: 29.690

3.  Difference in the diastolic left ventricular wall motion velocities between aortic and mitral regurgitation by pulsed tissue Doppler imaging.

Authors:  M Abe; T Oki; T Tabata; A Iuchi; S Ito
Journal:  J Am Soc Echocardiogr       Date:  1999-01       Impact factor: 5.251

4.  Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography.

Authors:  L Galiuto; G Ignone; A N DeMaria
Journal:  Am J Cardiol       Date:  1998-03-01       Impact factor: 2.778

5.  [Quantitative tissue Doppler echocardiography in comparison with M-mode measurements in healthy probands].

Authors:  T Bartel; S Müller; D Schürger; B Gassmann; V Rüttermann; R Erbel
Journal:  Z Kardiol       Date:  1997-02

6.  Quantitative assessment of alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography. Comparison with sonomicrometry and pressure-volume relations.

Authors:  J Gorcsan; D P Strum; W A Mandarino; V K Gulati; M R Pinsky
Journal:  Circulation       Date:  1997-05-20       Impact factor: 29.690

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  New method for evaluating left ventricular wall motion by color-coded tissue Doppler imaging: in vitro and in vivo studies.

Authors:  K Miyatake; M Yamagishi; N Tanaka; M Uematsu; N Yamazaki; Y Mine; A Sano; M Hirama
Journal:  J Am Coll Cardiol       Date:  1995-03-01       Impact factor: 24.094

9.  Evaluation of left ventricular early diastolic performance by color tissue Doppler imaging of the mitral annulus.

Authors:  N Ohte; H Narita; T Hashimoto; S Akita; K Kurokawa; T Fujinami
Journal:  Am J Cardiol       Date:  1998-12-01       Impact factor: 2.778

10.  Left ventricular systolic wall motion velocities along the long and short axes measured by pulsed tissue Doppler imaging in patients with atrial fibrillation.

Authors:  T Oki; A Iuchi; T Tabata; Y Mishiro; H Yamada; M Abe; Y Onose; T Wakatsuki; S Ito
Journal:  J Am Soc Echocardiogr       Date:  1999-02       Impact factor: 5.251

View more
  1 in total

1.  State diagrams of the heart--a new approach to describing cardiac mechanics.

Authors:  Matilda Larsson; Anna Bjällmark; Jonas Johnson; Reidar Winter; Lars-Ake Brodin; Stig Lundbäck
Journal:  Cardiovasc Ultrasound       Date:  2009-05-27       Impact factor: 2.062

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.