Literature DB >> 12537371

Development of an LC/MS method for the trace analysis of triacetone triperoxide (TATP).

Leo Widmer1, Stuart Watson, Konrad Schlatter, Andrew Crowson.   

Abstract

The detection and quantification of triacetone triperoxide (TATP) using LC/MS is investigated. GC/MS analysis of TATP is hindered by stationary phase activation in very short periods of time. Due to the lower temperatures used in LC. this problem is not encountered. This study presents a method that is suitable for the detection of TATP at levels as low as 100 pg microl(-1) (10 ng per 100 microl). Initial findings are also reported for the investigation of a secondary chromatographic peak, which is thought to be caused by separation of two conformers. This study concludes that LC/MS is a suitable technique for the analysis of trace levels of TATP.

Entities:  

Year:  2002        PMID: 12537371     DOI: 10.1039/b208350g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  7 in total

1.  Acetonitrile Ion Suppression in Atmospheric Pressure Ionization Mass Spectrometry.

Authors:  Kevin Colizza; Keira E Mahoney; Alexander V Yevdokimov; James L Smith; Jimmie C Oxley
Journal:  J Am Soc Mass Spectrom       Date:  2016-08-30       Impact factor: 3.109

2.  Reactions of Organic Peroxides with Alcohols in Atmospheric Pressure Chemical Ionization-the Pitfalls of Quantifying Triacetone Triperoxide (TATP).

Authors:  Kevin Colizza; Alexander Yevdokimov; Lindsay McLennan; James L Smith; Jimmie C Oxley
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-07       Impact factor: 3.109

3.  1,4-Benzoquinone as a Highly Efficient Dopant for Enhanced Ionization and Detection of Nitramine Explosives on a Single-Quadrupole Mass Spectrometer Fitted with a Helium-Plasma Ionization (HePI) Source.

Authors:  Julius Pavlov; David Douce; Steve Bajic; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2019-10-31       Impact factor: 3.109

4.  Expedite Fluorescent Sensor Prototype for Hydrogen Peroxide Detection with Long-Life Test Substrates.

Authors:  Qianqian Chen; Li Yang; Keke Guo; Jialin Yang; Ji-Min Han
Journal:  ACS Omega       Date:  2021-04-19

5.  A Novel Immunoreagent for the Specific and Sensitive Detection of the Explosive Triacetone Triperoxide (TATP).

Authors:  Maria Astrid Walter; Ulrich Panne; Michael G Weller
Journal:  Biosensors (Basel)       Date:  2011-07-07

6.  Development of a molecularly imprinted polymer-based sensor for the electrochemical determination of triacetone triperoxide (TATP).

Authors:  Samuel Kassahun Mamo; Jose Gonzalez-Rodriguez
Journal:  Sensors (Basel)       Date:  2014-12-05       Impact factor: 3.576

7.  Towards the fluorogenic detection of peroxide explosives through host-guest chemistry.

Authors:  Estefanía Almenar; Ana M Costero; Pablo Gaviña; Salvador Gil; Margarita Parra
Journal:  R Soc Open Sci       Date:  2018-04-11       Impact factor: 2.963

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.