Evaluation of hemolysis in the VentrAssist implantable rotary blood pump.

Natalie L James1, Carmel M Wilkinson, Nicole L Lingard, Anita L van der Meer, John C Woodard.   

Abstract

The VentrAssist implantable rotary blood pump (IRBP) is an implantable centrifugal blood pump with a hydrodynamically suspended impeller; optimal efficiency requires small running clearances (70-300 microm). The effect of running clearance and polish on hemolysis was evaluated in vitro. Three different human blood suspensions were compared: phosphate buffered saline (PBS), plasma volume expander (Hemaccel), and whole blood. The test conditions were: blood hematocrit 30%, flow rate 5 L/min, pressure across pump 100 mm Hg, 6 h flow period, and 37 degrees C. Normalized Index of Hemolysis (NIH) for the Biomedicus BP-80, used as a control, was: 0.0040 +/- 0.0023 (n = 9; x +/- SD) and 0.00014 +/- 0.00009 (n = 5) for pooled blood suspensions in PBS and Hemaccel respectively, and 0.00053 +/- 0.0002 (n = 3) in whole blood. Hemolysis was reduced by improved surface finish and unaffected by running clearance. NIH for the VentrAssist IRBP with 0.2 microm Ra surface finish was 0.000167 +/- 0.00007 (n = 4) g/100 L in whole human blood, demonstrating minimal hemolysis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12534722     DOI: 10.1046/j.1525-1594.2003.07188.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

1.  Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device.

Authors:  Jingchun Wu; Bradley E Paden; Harvey S Borovetz; James F Antaki
Journal:  Artif Organs       Date:  2009-10-12       Impact factor: 3.094

2.  Computational modeling of the Food and Drug Administration's benchmark centrifugal blood pump.

Authors:  Bryan C Good; Keefe B Manning
Journal:  Artif Organs       Date:  2020-02-16       Impact factor: 3.094

3.  Computational Fluid Dynamics and Experimental Characterization of the Pediatric Pump-Lung.

Authors:  Zhongjun J Wu; Barry Gellman; Tao Zhang; M Ertan Taskin; Kurt A Dasse; Bartley P Griffith
Journal:  Cardiovasc Eng Technol       Date:  2011-12-01       Impact factor: 2.495

4.  Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump.

Authors:  Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Theodosios Korakianitis
Journal:  ASAIO J       Date:  2018 Sep/Oct       Impact factor: 2.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.