Real-Time Four-dimensional Imaging of the Heart with Multi-Detector Row CT.

Kimiaki Saito1, Motoaki Saito, Shuhei Komatu, Kuni Ohtomo.   

Abstract

An interactive four-dimensional (4D) visualizing system for the heart was developed by the authors. The system realizes high-resolution three-dimensional (3D) imaging with temporal resolution in a beating heart by using eight or more data sets reconstructed from multi-detector row computed tomography (MDCT) with a retrospective electrocardiograph-gated reconstruction algorithm. The motion of heart walls, papillary muscles, septa, and valves can now be observed in 4D multiplanar reformations (MPRs), as with sonography, while coronary arteries, coronary sinuses, and cardiac veins can be analyzed during the optimal phase in 4D volume-rendering images, as with angiography. All parameters such as window width, window level, field of view, panning, tilt, thresholds, opacity, color, and segmentation function are completely interactive in 4D imaging. Two longitudinal views and one latitudinal view of a heart can be simultaneously visualized in the three relative 4D MPR views. These newly developed capabilities in viewing both 3D volume and temporal resolution data, functional data, and even multiphase data with registration add considerable diagnostic potential. The advent of this real-time 4D visualizing system has enhanced the capabilities of MDCT. Copyright RSNA, 2003

Mesh:

Year:  2003        PMID: 12533663

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  4 in total

Review 1.  OsiriX: an open-source software for navigating in multidimensional DICOM images.

Authors:  Antoine Rosset; Luca Spadola; Osman Ratib
Journal:  J Digit Imaging       Date:  2004-06-29       Impact factor: 4.056

Review 2.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

3.  Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.

Authors:  Georg Mühlenbruch; Tobias Seyfarth; Chee Siong Soo; Namasivayam Pregalathan; Andreas Horst Mahnken
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

4.  Sleep-Induced Glottis Closure in Multiple System Atrophy Evaluated by Four-Dimensional Computed Tomography.

Authors:  Rumi Ueha; Eriko Maeda; Kenji Ino; Takahiro Shimizu; Taku Sato; Takao Goto; Tatsuya Yamasoba
Journal:  Front Med (Lausanne)       Date:  2020-04-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.