Hemobahn stent-grafts for treatment of femoropopliteal arterial obstructions: midterm results of a prospective trial.

Thomas Jahnke1, Reimer Andresen, Stefan Müller-Hülsbeck, Fritz K W Schäfer, Götz Voshage, Martin Heller, Joachim Brossmann.   

Abstract

PURPOSE: To report a prospective study to evaluate safety, effectiveness, and midterm patency of self-expanding stent-grafts in patients with femoropopliteal occlusive disease.
MATERIALS AND METHODS: Sixty-three Hemobahn stent-grafts were used in 52 patients for treatment of medium- or long-segment (>3 cm) occlusions (82.7%) and stenoses (17.3%) of the femoropopliteal artery. The mean length of vessel segments covered was 10.9 cm +/- 5.13. Follow-up with documentation of clinical symptoms, assessment of Rutherford clinical stage of peripheral vascular disease, and color-coded duplex sonography was performed at discharge, at 1, 3, 6, 12, 18, and 24 months after implantation, and yearly thereafter. Mean follow-up duration was 23.8 months +/- 6.9 (range, 8-36 mo). Follow-up data at 12 and 24 months after treatment were available for 47 of 52 (90.4%) and 31 of 52 patients (59.6%), respectively.
RESULTS: Device implantation was technically successful in all 52 patients, yielding an overall technical success rate of 100%. Procedure-related complications were observed in 12 of 52 patients (23.1%) and consisted of distal embolization (n = 4, 7.7%), minor groin hematoma (n = 7, 13.5%), and arteriovenous fistula (n = 1, 1.9%), but prolonged hospitalization and further medical, interventional, or surgical measures were not required. Stent-graft placement induced an initial improvement of the mean resting ankle-brachial index from 0.54 +/- 0.12 to 0.89 +/- 0.14 (P <.01). Primary patency rates at 12 and 24 months were 78.4% +/- 5.8 and 74.1% +/- 6.2, respectively. Primary assisted patency rates were 82.4% +/- 5.3 at 12 months and 80.3% +/- 5.6 at 24 months. Secondary patency rates at 12 and 24 months were 88.3% +/- 4.5 and 83.2% +/- 5.5, respectively. There was no significant difference (log-rank test, P >.3) between primary patency rates in patients grouped according to lengths of implanted grafts (ie, length of the treated lesions).
CONCLUSION: Endovascular placement of Hemobahn stent-grafts for percutaneous treatment of medium- to long-segment high-grade stenoses and occlusions of the femoropopliteal artery is a safe procedure with excellent initial success rates and promising midterm results.

Entities:  

Mesh:

Year:  2003        PMID: 12525585     DOI: 10.1097/01.rvi.0000052290.26939.cb

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  5 in total

Review 1.  [Rational minimally invasive treatment of pAOD: when should a conservative approach, PTA, or stent be chosen?].

Authors:  S Müller-Hülsbeck
Journal:  Radiologe       Date:  2006-11       Impact factor: 0.635

2.  Evaluation of peripheral atherosclerosis: a comparative analysis of angiography and intravascular ultrasound imaging.

Authors:  Zachary M Arthurs; Paul D Bishop; Lindsay E Feiten; Matthew J Eagleton; Daniel G Clair; Vikram S Kashyap
Journal:  J Vasc Surg       Date:  2010-01-15       Impact factor: 4.268

3.  Inhibition of edge stenosis of endografts in swine iliac arteries by a novel endograft with biodegradable coating at both ends.

Authors:  Qing Zhu; Ping Ye; Jinyao Wang; Zhaohua Chang
Journal:  JVS Vasc Sci       Date:  2021-05-25

4.  Viabahn for femoropopliteal in-stent restenosis.

Authors:  Owayed Al Shammeri; Fahad Bitar; Jaime Ghitelman; Peter A Soukas
Journal:  Ann Saudi Med       Date:  2012 Nov-Dec       Impact factor: 1.526

5.  Viabahn stent graft compared with prosthetic surgical above-knee bypass in treatment of superficial femoral artery disease: Long-term results of a retrospective analysis.

Authors:  Narges Waezi; Shekhar Saha; Ioannis Bougioukas; Alexander Emmert; Bernhard Christoph Danner; Hassina Baraki; Ingo Kutschka; Dieter Zenker; Tomislav Stojanovic; Ahmad Fawad Jebran
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.