Literature DB >> 12510905

Preload and haemodynamic assessment during liver transplantation: a comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniques.

G Della Rocca1, M G Costa, C Coccia, L Pompei, P Pietropaoli.   

Abstract

BACKGROUND AND
OBJECTIVE: Liver transplantation is characterized by several changes in intravascular blood volume due to vasodilatation based on neurohumoral mediators, intraoperative bleeding and anaesthesia technique effects. Today, with the transpulmonary indicator dilution technique, cardiac index (CIart) can be evaluated and preload assessed in terms of the intrathoracic blood volume index (ITBVI). The aim was to analyse in patients undergoing liver transplantation two preload variables, pulmonary artery occlusion pressure (PAOP) and ITBVI with respect to cardiac index (CIpa) and stroke volume index (SVIpa), the correlation between ITBVI and PAOP, and secondary the relationship between the changes (delta) of ITBVI and PAOP and the changes of CIpa and SVIpa, and the relationships between deltaITBVI and deltaPAOP. The reproducibility and precision of all CIart and CIpa measurements were also evaluated.
METHODS: A prospective study was performed in 60 patients monitored with a pulmonary artery catheter and with the PiCCO system. The variables were evaluated with a linear regression model.
RESULTS: Linear regression analysis between ITBVI-CIpa and ITBVI-SVIpa were r2 = 0.47 (P < 0.0001) and r2 = 0.55 (P < 0.0001) respectively, while PAOP poorly correlated to CIpa (r2 = 0.02), SVIpa (r2 = 0.015) and ITBVI (r2 = 0.002). Only changes in ITBVI were correlated with changes in CIpa (delta1, r2 = 0.37; delta2, r2 = 0.32), and SVIpa (delta1, r2 = 0.60; delta2, r2 = 0.47). The mean bias between CIart and CIpa was 0.13 L min(-1) m(-2) (2 SD = 1.04L min(-1) m(-2)) (r2 = 0.86, P < 0.0001).
CONCLUSIONS: In comparison with PAOP, ITBVI seems a more reliable indicator of cardiac preload in patients undergoing liver transplantation.

Entities:  

Mesh:

Year:  2002        PMID: 12510905     DOI: 10.1017/s0265021502001394

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  12 in total

1.  Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi
Journal:  Neurocrit Care       Date:  2010-08       Impact factor: 3.210

2.  Effects of volumetric vs. pressure-guided fluid therapy on postoperative inflammatory response: a prospective, randomized clinical trial.

Authors:  Tamas Szakmany; Ildiko Toth; Zsolt Kovacs; Tamas Leiner; Andras Mikor; Tamas Koszegi; Zsolt Molnar
Journal:  Intensive Care Med       Date:  2005-04-06       Impact factor: 17.440

Review 3.  Perioperative monitoring in liver transplant patients.

Authors:  Shweta Singh; Vaibhav Nasa; Manish Tandon
Journal:  J Clin Exp Hepatol       Date:  2012-09-21

4.  Stroke volume variation as a guide to fluid administration in morbidly obese patients undergoing laparoscopic bariatric surgery.

Authors:  Anil Kumar Jain; Amitabh Dutta
Journal:  Obes Surg       Date:  2010-03-09       Impact factor: 4.129

Review 5.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

6.  Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006.

Authors:  Massimo Antonelli; Mitchell Levy; Peter J D Andrews; Jean Chastre; Leonard D Hudson; Constantine Manthous; G Umberto Meduri; Rui P Moreno; Christian Putensen; Thomas Stewart; Antoni Torres
Journal:  Intensive Care Med       Date:  2007-04       Impact factor: 17.440

Review 7.  Haemodynamic monitoring in acute heart failure.

Authors:  Maurizio Cecconi; Toby E Reynolds; Nawaf Al-Subaie; Andrew Rhodes
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.214

8.  Is stroke volume variation a useful preload index in liver transplant recipients? A retrospective analysis.

Authors:  Sung-Hoon Kim; Gyu-Sam Hwang; Seon-Ok Kim; Young-Kug Kim
Journal:  Int J Med Sci       Date:  2013-04-18       Impact factor: 3.738

9.  Haemodynamic effects of plasma-expansion with hyperoncotic albumin in cirrhotic patients with renal failure: a prospective interventional study.

Authors:  Andreas Umgelter; Katrin Wagner; Wolfgang Reindl; Nils Nurtsch; Wolfgang Huber; Roland M Schmid
Journal:  BMC Gastroenterol       Date:  2008-08-27       Impact factor: 3.067

10.  Anaesthesia and intensive care for simultaneous liver-kidney transplantation: A single-centre experience with 12 recipients.

Authors:  Akila Rajakumar; Shiwalika Gupta; Selvakumar Malleeswaran; Joy Varghese; Ilankumaran Kaliamoorthy; Mohamed Rela
Journal:  Indian J Anaesth       Date:  2016-07
View more