Literature DB >> 12490876

Plasma arc curing lights for orthodontic bonding.

Arndt Klocke1, Heike M Korbmacher, Lothar G Huck, Bärbel Kahl-Nieke.   

Abstract

Xenon plasma arc lights were introduced recently for light-cured orthodontic bonding. Compared with a conventional tungsten-quartz-halogen light source, these high-intensity lights promise a dramatic reduction in curing time. The purpose of this in vitro investigation was to evaluate bond strength with 2 commercially available plasma arc lights and reduced curing intervals. Brackets were bonded to 150 extracted human teeth (75 premolars, 75 incisors) with a composite adhesive. Intervals of 2 and 6 seconds were used for curing with the plasma arc lights; a control group was bonded with a halogen light source and 20 seconds of light exposure per bracket. Bond strength testing was performed with a universal testing machine. A substantial reduction in curing time was possible with both plasma arc units. Significantly lower bond strength values were found for premolar brackets bonded with plasma arc curing lights and the shortest curing interval of 2 seconds compared with the longer curing time of 6 seconds or the standard curing time with the halogen light. Although 2 seconds of curing might be adequate to achieve acceptable bond strength values for the incisors, the Weibull analysis indicated a higher probability of bond failure for premolar brackets in particular. Six seconds of curing time is recommended for bonding stainless steel brackets with xenon plasma arc light sources.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12490876     DOI: 10.1067/mod.2002.126897

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Self-etch adhesives for the bonding of orthodontic brackets: faster, stronger, safer?

Authors:  Timea Lamper; Nicoleta Ilie; Karin C Huth; Ingrid Rudzki; Andrea Wichelhaus; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2013-02-14       Impact factor: 3.573

2.  Effect of Dental Chair Light on Enamel Bonding of Orthodontic Brackets Using Light Cure Based Adhesive System: An In-Vitro Study.

Authors:  Anil Tiwari; Tarulatha Shyagali; Sarvraj Kohli; Rishi Joshi; Abhishek Gupta; Rana Tiwari
Journal:  Acta Inform Med       Date:  2016-11-01

3.  Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing.

Authors:  Mohammad Hossein Toodehzaeim; Alireza Danesh Kazemi; Hossein Agha Aghili; Kazem Barzegar; Taranom Fallahtafti
Journal:  Dent Res J (Isfahan)       Date:  2012-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.